323167 TE Connectivity, 323167 Datasheet - Page 4

STRATO-THERM, HR 8 5/16 NIPL

323167

Manufacturer Part Number
323167
Description
STRATO-THERM, HR 8 5/16 NIPL
Manufacturer
TE Connectivity
Series
323r
Type
Closed Barrelr
Datasheets

Specifications of 323167

Rohs Compliant
YES
Product
Rings
Wire Size (awg)
8
Stud / Tab Size
5/16 (M8)
Insulation
Not Insulated
Gender
Female
Contact Plating
Nickel
Contact Material
Copper
Operating Temperature Range
343 C
Terminal Shape
Ring Tongue
Receptacle Style
Straight
Body Style
SOLISTRAND, STRATO-THERM
Barrel Type
Closed Barrel
Wire/cable Type
Regular Wire
Insulation Support
Non-Insulation Support
Stud Diameter (mm [in])
8.33 [0.328]
Stud Size
5/16 [M8]
Shape
RING-084
Heavy Duty
No
Finish
Nickel
Wire/cable Size (cma)
13,100 – 20,800
Wire Range (mm [awg])
8.00² [8]
Tongue Material Thickness (mm [in])
1.30 [0.051]
Government/industry Qualification
No
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
High Temperature Rating (°c [°f])
343 [650]
Packaging Method
Loose Piece
Lead Free Status / Rohs Status
 Details
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of 10 term inals of
each wire size.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.
W ire Size
1/0
8
6
4
2
Millivolt Drop & Tensile Strength Requirem ents
Test Current
101
135
181
245
73
Term inal Millivolt Drop
Figure 3
(m axim um )
5.0
5.0
5.0
5.0
5.0
(pounds m inim um )
Tensile Strength
225
300
400
550
700
108-2193
4 of 4