INT-1532-L-5-M-001=1 TE Connectivity, INT-1532-L-5-M-001=1 Datasheet - Page 12

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-M-001=1

Manufacturer Part Number
INT-1532-L-5-M-001=1
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-M-001=1

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
Specifications
Programmable Display
A two-button interface on the front panel of Integra 1530 units enables the simple
programming of VT and CT ratio settings, configuring selected communication options,
and adjusting operating parameters. To prevent unauthorised access to configuration
settings, all set-up screens offer password protection. Once configured, status
information can be viewed by scrolling through 15 screens featuring a high contrast
3-line, 4-digit LED display with separate annunicators for each of the 34 measured
parameters. Optional pulsed, analogue or digital outputs allow enhanced status
information of up to 50 measured parameters to be communicated into building
management systems.
Programmable Parameters
Parameter
Password:
Primary current:
VT primary:
Secondary voltage:
Demand integration time:
Reset:
Pulse output duration:
Pulse rate divisors:
RS485 interface baud rate:
RS485 parity:
Modbus address:
Analogue outputs:
Input
Nominal input voltage:
Max continuous input voltage:
Max short duration input voltage: 2 x for 1 second, repeated 10 times at 10
System VT ratios (primary):
Nominal input voltage burden:
Nominal input current:
System CT primary values:
Max continuous input current:
Max short duration current input: 20 x for 1 second, repeated 5 times at
Nominal input current burden:
Outputs (optional)
RS485 communications:
Baud rates:
Pulsed:
Pulse duration:
Pulsed outputs:
Analogue outputs:
Auxiliary
Standard nominal supply voltage: 100-250V, ac or dc
AC supply frequency range:
AC supply burden:
Optional auxiliary dc supply:
dc supply burden:
Range
4-digit, 0000-9999
Max 9999:5A (360MW max**)
400kV (360MW max**)
Nominal system voltage
** maximum VT and CT ratios are limited so that
the combination of primary voltage and current
does not exceed 360MW at 120% of relevant
input
8, 15, 20, 30 and 60 minutes
Max demand & active energy registers
60, 100, 200 ms
1, 10, 100, 1000
2.4, 4.8, 9.6, 19.2kB
Odd / even / no, 1 or 2 stop bits
1-247
User definable
57.7 to 277V L-N, 100 to 480V L-L
120% of nominal
second intervals
Any value up to 400kV **
< 0.2 VA
5A (1A option)
9999:5A or 9999:1A max 360MW **
120% nominal
5 second intervals
< 0.6 VA
** maximum VT and CT ratios are limited so the
combination of primary voltage and current does
not exceed 360MW at 120% of relevant input
2-wire half duplex
2400, 4800, 9600, 19200
Clean contact SPNO
60, 100 or 200 milliseconds
1 or 2
1 or 2
(85-287V, ac absolute)
(85-312V, dc absolute)
45-66Hz
6VA
12-48V, dc
(10.2-60V, dc absolute)
6 VA
Measurement and Display
Up to 34 electrical and power quality
parameters can be configured and
displayed on the Integra 1530 unit.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
Enhanced status information of up
to 50 parameters can be
communicated into building
management systems via optional
pulsed, analogue and digital outputs.
System volts
System current
System kW
System volts THD %
System current THD %
Volts L1–N (4-wire only)
Volts L2–N (4-wire only)
Volts L3–N (4-wire only)
Volts L1–L2
Volts L2–L3
Volts L3–L1
Volts line 1 THD %
Volts line 2 THD %
Volts line 3 THD %
Current L1
Current L2
Current L3
Current line 1 THD %
Current line 2 THD %
Current line 3 THD %
Neutral current (4-wire only)
Frequency
Power factor
kVAr
kVA
kW
kWh import (7-digit resolution)
kVArh import (7-digit resolution)
kWh export (7-digit resolution)
kVArh export (7-digit resolution)
kW demand
Current demand
kW maximum demand
Current maximum demand
11