INT-1532-L-5-M-001=1 TE Connectivity, INT-1532-L-5-M-001=1 Datasheet - Page 15

DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V

INT-1532-L-5-M-001=1

Manufacturer Part Number
INT-1532-L-5-M-001=1
Description
DIGITAL PANEL METER, 4-DIGIT, 57.7V TO 139V / 100V TO 240V
Manufacturer
TE Connectivity
Datasheet

Specifications of INT-1532-L-5-M-001=1

No. Of Digits / Alpha
4
Meter Function
Digital
Meter Range
0mA To 20mA
Digit Height
96mm
Supply Voltage Range
57.7V To 139V / 100V To 240V
Power Consumption
3W
14
Import and Export Connections
The connection diagrams shown
assume an import power
configuration, therefore any power
flow towards the load will register as
importing energy.
If power flows away from the load in
an export power situation, this power
will register as exporting energy.
Dimensions
MAX PANEL THICKNESS 0.19", 5mm
96mm
3.78"
PANEL CUT-OUT
5.87" 149mm
5.67" 144mm
92mm
3.62"
FRONT DISPLAY
96mm
AREA
3.78"
92mm
3.62"
Wiring
Input connections are made directly to shrouded screw-clamp terminals. Terminals for
both current and voltage connections are sized to accept two #12 AWG (3mm
stranded wires. Connections for auxiliary power, pulsed and analogue options are via
screw-clamp connectors. Connectors offer retained wire protection leaves suitable for
one #13 AWG (2.5mm
screw-clamp connection, wire protection leaves and sized to accept one #15 AWG
(1.5mm
Auxiliary Supply
The Integra 1530 should ideally be powered from a dedicated supply, either
100–250V ac or dc (85–280V ac absolute or 85–312V dc absolute) or 12-48V dc
(10.2–60V dc absolute). However the device may be powered from a signal source,
provided the source remains within the working range of the chosen auxiliary supply.
Fusing
It is recommended that all voltage lines be fitted with 1 amp fuses.
Safety/Ground Connections
For safety reasons, all CT secondary connections should be grounded in accordance
with local regulations.
3-phase 4-wire with neutral CT
2
) solid or stranded wire.
3-phase 3-wire
Single-phase
2
) solid or stranded wire. Digital interface connections are also via
Single-phase 3-wire
3-phase 4-wire
2
) solid or

Related parts for INT-1532-L-5-M-001=1