04023J3R9CBSTR AVX Corporation, 04023J3R9CBSTR Datasheet - Page 77

CAPACITOR, ACCU-P 3.9PF 25V 0402CAPACITOR, ACCU-P 3.9PF 25V 0402

04023J3R9CBSTR

Manufacturer Part Number
04023J3R9CBSTR
Description
CAPACITOR, ACCU-P 3.9PF 25V 0402CAPACITOR, ACCU-P 3.9PF 25V 0402
Manufacturer
AVX Corporation
Datasheet

Specifications of 04023J3R9CBSTR

Capacitance
3.9PF
Voltage Rating, Dc
25V
Capacitor Dielectric Type
CERAMIC MULTI-LAYER
Tolerance,
6.4%
Tolerance, -
6.4%
Temp, Op. Max
125(DEGREE C)
Temp, Op.
ROHS COMPLIANT
3
Thin-Film Directional Couplers
DB0805 3dB 90° Test Jigs
GENERAL DESCRIPTION
These jigs are designed for testing the DB0805 3dB 90°
Couplers using a Vector Network Analyzer.
They consist of a dielectric substrate, having 50Ω microstrips
as conducting lines and a bottom ground plane located at a
distance of 0.254mm from the microstrips.
The substrate used is Neltec’s NH9338ST0254C1BC.
MEASUREMENT PROCEDURE
When measuring a component, it can be either soldered or
pressed using a non-metallic stick until all four ports touch
the appropriate pads. Set the VNA to the relevant frequency
band. Connect the VNA using a 10dB attenuator on the jig
76
Connector 4
Place the coupler on the
Input (Coupler)
50Ω (Coupler)
To measure
Connector 1 (Jig) ➜ Port 1 (VNA) Connector 3 (Jig) ➜ Port 2 (VNA)
Connector 2 (Jig) ➜ 50Ω
To measure
Connector 1 (Jig) ➜ Port 1 (VNA) Connector 3 (Jig) ➜ 50Ω
Connector 2 (Jig) ➜ 50Ω
To measure
Connector 1 (Jig) ➜ 50Ω
Connector 2 (Jig) ➜ 50Ω
Measurement Jig
R. Loss
R. Loss
Isolation
➜ Connector 1 (Jig)
➜ Connector 2 (Jig)
and
and
Connector 1
Connector 3
connect:
I. Loss 1
I. Loss 2
measurement jig
Connector 2
connect:
connect:
Connector 4 (Jig) ➜ 50Ω
Connector 4 (Jig) ➜ Port 2 (VNA)
Connector 3 (Jig) ➜ Port 1 (VNA)
Connector 4 (Jig) ➜ Port 2 (VNA)
as follows:
Load &
Through
Output 1 (Coupler) ➜ Connector 3 (Jig)
Output 2 (Coupler) ➜ Connector 4 (Jig)
The connectors are SMA type (female), ‘Johnson Components
Inc.’ Product P/N: 142-0701-841.
Both a measurement jig and a calibration jig are provided.
The calibration jig is designed for a full 2-port calibration, and
consists of an open line, short line and through line. LOAD
calibration can be done by a 50Ω SMA termination.
terminal connected to port 2. Follow the VNA’s instruction
manual and use the
calibration in the required bandwidths.
Load &
Through
Calibration Jig
Open
Line
calibration jig
Connector
Johnson
P/N 142-0701-841
Short Line
to GND
to perform a full 2-port

Related parts for 04023J3R9CBSTR