ADM1065
SEQUENCING ENGINE
OVERVIEW
The ADM1065 sequencing engine (SE) provides the user with
powerful and flexible control of sequencing. The SE implements
a state machine control of the PDO outputs with state changes
conditional on input events. SE programs can enable complex
control of boards such as power-up and power-down sequence
control, fault event handling, and interrupt generation on
warnings, among others. A watchdog function that verifies the
continued operation of a processor clock can be integrated into
the SE program. The SE can also be controlled via the SMBus,
giving software or firmware control of the board sequencing.
The SE state machine comprises 63 state cells. Each state has the
following attributes:
Table 7. Sample Sequence State Entries
State
IDLE1
IDLE2
EN3V3
DIS3V3
EN2V5
DIS2V5
FSEL1
FSEL2
PWRGD
Monitors signals indicating the status of the 10 input pins,
VP1 to VP4, VH, and VX1 to VX5.
Can be entered from any other state.
Three exit routes move the state machine onto a next state:
sequence detection, fault monitoring, and timeout.
Delay timers for the sequence and timeout blocks can be
programmed independently, and changed with each state
change. The range of timeouts is from 0 ms to 400 ms.
Output condition of the 10 PDO pins is defined and fixed
within a state.
Transition from one state to the next is made in less than
20 μs, which is the time needed to download a state
definition from EEPROM to the SE.
Sequence
If VX1 is low, go to State IDLE2.
If VP1 is okay, go to State EN3V3.
If VP2 is okay, go to State EN2V5.
If VX1 is high, go to State IDLE1.
If VP3 is okay, go to State PWRGD.
If VX1 is high, go to State IDLE1.
If VP3 is not okay, go to State DIS2V5.
If VP2 is not okay, go to State DIS3V3.
If VX1 is high, go to State DIS2V5.
Timeout
If VP2 is not okay after 10 ms,
go to State DIS3V3.
If VP3 is not okay after 20 ms,
go to State DIS2V5.
Rev. C | Page 14 of 28
The ADM1065 offers up to 63 state definitions. The signals
monitored to indicate the status of the input pins are the outputs
of the SFDs.
WARNINGS
The SE also monitors warnings. These warnings can be generated
when the ADC readings violate their limit register value or when
the secondary voltage monitors on VPx and VH are triggered.
The warnings are OR’ e d together and are available as a single
warning input to each of the three blocks that enable exiting a state.
SMBus JUMP (UNCONDITIONAL JUMP)
The SE can be forced to advance to the next state unconditionally.
This enables the user to force the SE to advance. Examples of
the use of this feature include moving to a margining state or
debugging a sequence. The SMBus jump or go-to command can
be seen as another input to sequence and timeout blocks to provide
an exit from each state.
Monitor
If VP1 is not okay, go to State IDLE1.
If VP1 or VP2 is not okay, go to State FSEL2.
If VP1 or VP2 is not okay, go to State FSEL2.
If VP1 is not okay, go to State IDLE1.
If VP1, VP2, or VP3 is not okay, go to State FSEL1.
MONITOR
FAULT
Figure 20. State Cell
STATE
SEQUENCE
TIMEOUT