HI-8282APQI Holt Integrated Circuits, HI-8282APQI Datasheet - Page 6

no-image

HI-8282APQI

Manufacturer Part Number
HI-8282APQI
Description
Manufacturer
Holt Integrated Circuits
Datasheet

Specifications of HI-8282APQI

Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Package Type
PQFP
Rad Hardened
No
Lead Free Status / Rohs Status
Not Compliant
FUNCTIONAL DESCRIPTION (cont.)
REPEATER OPERATION
Repeater mode of operation allows a data word received by the
HI-8282 to be placed directly into the Transmit FIFO for
transmission.
receiver shift register, the
on the SEL line and
for normal receiver operation, placing the lower byte (16) of the
data word on the data bus. By strobing
EN, the byte is also transferred into the Transmit FIFO.
then taken high and
TIMING DIAGRAMS
ARINC DATA
ENABLE BYTE ON BUS
429DO
429DO
DATA READY FLAG
BYTE SELECT
After a 32-bit word has been shifted into the
DATA BUS
DATA BUS
CWSTR
EN
BIT 31
EN
DATA
SEL
D/R
is strobed. This is the same procedure as
ARINC BIT
EN
is strobed again to place the upper data
BIT 30
D/R
flag goes low. A logic "0" is placed
NULL
BIT 32
t
PL1
DATA
D/R
DON'T CARE
at the same time as
BIT 31
DATA RATE - EXAMPLE PATTERN
NULL
HOLT INTEGRATED CIRCUITS
t
ENDATA
t
D/REN
LOADING CONTROL WORD
t
CWSTR
t
RECEIVER OPERATON
SELEN
SEL is
DATA
HI-8282A
t
CWSET
BIT 32
VALID
6
BYTE 1 VALID
NULL
word byte onto the data bus. By strobing
EN
FIFO. The data word is now ready for transmission, according to
the parity programmed into the Control Word register.
In normal (non-repeater) operation, either byte of the received
data word may be read first by using the SEL input. During
repeater operation however, data word lower byte must always be
read first. While the data is being read, it is loading concurrently
into the Transmit FIFO, which always loads lower byte first.
t
, the second data word byte is also transferred to the Transmit
ENSEL
t
CWHLD
t
DATAEN
DON'T CARE
WORD GAP
t
ENEN
t
ENDATA
t
SELEN
t
END/R
t
EN
NEXT WORD
BYTE 2 VALID
PL2
BIT 1
t
ENSEL
at the same time as
DON'T CARE
t
DATAEN

Related parts for HI-8282APQI