SRI4K-A3T/1GE STMicroelectronics, SRI4K-A3T/1GE Datasheet - Page 25

no-image

SRI4K-A3T/1GE

Manufacturer Part Number
SRI4K-A3T/1GE
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of SRI4K-A3T/1GE

Operating Temperature (max)
85C
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant
COMPLETION() Command
Command Code = 0Fh
On receiving the COMPLETION() command, a
SRI4K in SELECTED state switches to DEACTI-
VATED state and stops decoding any new com-
mands. The SRI4K is then locked in this state until
a complete reset (tag out of the field range). A new
Figure 37. COMPLETION Request Format
Request parameters:
Figure 38. COMPLETION Response Format
Figure 39. COMPLETION Frame Exchange Between Reader and SRI4K
No parameter
Reader
SRI4K
SOF
SOF
0Fh
COMPLETION
CRC L
0Fh
CRC H EOF
No Response
CRC L
8 bits
SRI4K can thus be accessed through a SELECT()
command without having to remove the previous
one from the field. The COMPLETION() command
does not generate a response.
All SRI4K devices not in SELECTED state ignore
the COMPLETION() command.
CRC H
8 bits
No Response
EOF
AI07679
AI07680
AI10888
SRI4K
25/41

Related parts for SRI4K-A3T/1GE