Specifications of EP1SGX40GF1020I6

Number Of Logic Elements/cells
41250
Number Of Labs/clbs
4125
Total Ram Bits
3423744
Number Of I /o
624
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
1020-FBGA
Family Name
Stratix GX
Number Of Logic Blocks/elements
41250
# I/os (max)
624
Frequency (max)
5GHz
Process Technology
SRAM
Operating Supply Voltage (typ)
1.5V
Logic Cells
41250
Ram Bits
3423744
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
1020
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
Quantity:
1 238
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1SGX40GF1020I6
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1SGX40GF1020I6
Manufacturer:
ALTERA
0
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
XILINX
0
Part Number:
EP1SGX40GF1020I6N
Manufacturer:
ALTERA
0
Operating Conditions
6–14
Stratix GX Device Handbook, Volume 1
Note to
(1)
V
V
V
V
ΔV
V
ΔV
R
Table 6–13. 3.3-V LVDS I/O Specifications
CCIO
I D
I C M
OD
OCM
L
Symbol
OD
OCM
(1)
For up to 1 Gbps in DPA mode and 840 Mbps in non-DPA mode
(1)
Table
6–13:
I/O supply voltage
Input differential voltage
swing (single-ended)
Input common-mode
voltage
Differential output voltage
(single ended)
Change in V
high and low
Output common-mode
voltage
Change in V
high and low
Receiver differential input
resistor, external
Parameter
OD
OCM
Tables 6–13
bus hold parameters for 1.5-V Stratix GX devices. Notes for
through
between
between
6–33
0.1 V < V
W = 1 through 10
1.1 V < V
W = 1
1.1 V < V
W = 2 through 10
1.6 V < V
W = 1 through 10
LVDS
0.3 V < V
W = 1 through 10
LVDS
0.3 V < V
W = 1 through 10
LVDS
0.2 V < V
W = 1
LVDS
0.1 V < V
W = 2 through 10
R
R
R
R
through
L
L
L
L
immediately follow
= 100 Ω
= 100 Ω
= 100 Ω
= 100 Ω
Conditions
C M
C M
C M
C M
I D
I D
I D
I D
6–33
< 1.0 V
< 1.0 V
< 1.0 V
< 1.0 V
< 1.1 V
< 1.6 V
< 1.6 V
< 1.8 V
provide information about specifications and
Minimum
3.135
1,600
1,100
1,100
1,125
Table
300
200
100
300
100
250
90
6–33.
Typical
1,200
375
100
3.3
Maximum
Altera Corporation
3.465
1,000
1,000
1,000
1,000
1,100
1,800
1,600
1,600
1,375
550
110
50
50
Tables 6–14
June 2006
Units
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
V
Ω