20-101-1247 Rabbit Semiconductor, 20-101-1247 Datasheet - Page 107

CORE MODULE RCM5450W

20-101-1247

Manufacturer Part Number
20-101-1247
Description
CORE MODULE RCM5450W
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 20-101-1247

Module/board Type
MPU Core Module
Wireless Frequency
73.73 MHz
For Use With/related Products
RCM5450W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
316-1149
RS-232 flow control on an RS-232 port is initiated in software using the
trolOn
of the flow control lines are specified using a set of five macros.
Standard 3-wire RS-232 communication using Serial Ports C and D is illustrated in the
following sample code.
OEM User’s Manual
SERX_RTS_PORT—Data register for the parallel port that the RTS line is on (e.g., PCDR).
SERA_RTS_SHADOW—Shadow register for the RTS line's parallel port (e.g., PCDRShadow).
SERA_RTS_BIT—The bit number for the RTS line.
SERA_CTS_PORT—Data register for the parallel port that the CTS line is on (e.g., PCDRShadow).
SERA_CTS_BIT—The bit number for the CTS line.
#define CINBUFSIZE
#define COUTBUFSIZE 15
#define DINBUFSIZE
#define DOUTBUFSIZE 15
#define MYBAUD 115200
#endif
main(){
}
function call from
serCopen(_MYBAUD);
serDopen(_MYBAUD);
serCwrFlush();
serCrdFlush();
serDwrFlush();
serDrdFlush();
serCclose(_MYBAUD);
serDclose(_MYBAUD);
RS232.LIB
15
15
// set baud rate
// set size of circular buffers in bytes
// open Serial Ports C and D
// flush their input and transmit buffers
// close Serial Ports C and D
, where
X
is the serial port (C or D). The locations
serXflowcon-
101

Related parts for 20-101-1247