20-101-1112 Rabbit Semiconductor, 20-101-1112 Datasheet - Page 31

MODULE RABBITCORE RCM4010

20-101-1112

Manufacturer Part Number
20-101-1112
Description
MODULE RABBITCORE RCM4010
Manufacturer
Rabbit Semiconductor
Datasheet

Specifications of 20-101-1112

Module/board Type
MPU Core Module
Product
Microcontroller Modules
Core Processor
Rabbit 4000
Clock Speed
58.98 MHz
Interface Type
Ethernet, Serial
Flash
512 KB
Timers
10 x 8 bit, 1 x 10 bit, 1 x 16 bit
Operating Supply Voltage
3 V to 3.6 V
Board Size
47 mm x 61 mm x 20 mm
Core
RCM4010
Processor Series
RCM4000
Silicon Manufacturer
Rabbit
Core Architecture
Rabbit 4000
Silicon Core Number
RCM4010
Silicon Family Name
RCM4000
Kit Contents
Board
Development Tool Type
Hardware / Software - Dev Kit (Dev Tool)
Rohs Compliant
Yes
For Use With/related Products
RCM4010
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q3413688
User’s Manual
Follow the remaining steps carefully in Tera Term to avoid overwriting previously
saved calibration data when using same the file name.
Tera Term is now ready to log all data received on the serial port to the file you specified.
You are now ready to compile and run this sample program. A message will be displayed
in the Tera Term display window once the sample program is running.
Enter the serial number of your RabbitCore module in the Tera Term display window,
then press the
calibration data.
Now select
separate pop-up window minimized at the bottom of your PC screen. This finishes the
logging and closes the file.
Open your data file and verify that the calibration data have been written properly. A
sample is shown below.
Serial port transmission
========================
Uploading calibration table . . .
Enter the serial number of your controller = 9MN234
SN9MN234
ADSE
0
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
1
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
ADDF
0
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
2
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,float_gain,float_offset,
ADMA
3
float_gain,float_offset,
4
float_gain,float_offset,
END
|
|
|
|
|
|
CLOSE
ENTER
Enable the
Select the
Baud rate 19,200 bps, 8 bits, no parity, 1 stop bit
Enable
Feed options —
from within the Tera Term LOG window, which will likely be a
key. The Tera Term display window will now display the
OPEN
File APPEND
Local Echo
option at the right-hand side of the dialog box
Receive = CR
option
option at the bottom of the dialog box
,
Transmit = CR + LF
25

Related parts for 20-101-1112