2.3 Starting Dynamic C
Once the RCM3200 is connected as described in the preceding pages, start Dynamic C by
double-clicking on the Dynamic C icon on your desktop or in your
Code and BIOS in Flash, Run in RAM
> Project Options
If you are using a USB port to connect your computer to the RCM3200 module, choose
Options > Project Options
Communications
2.4 Run a Sample Program
Use the
SAMPLES
window will open on your PC and will display a small square bouncing around in a box.
This program shows that the CPU is working. The sample program described in
Section 6.5, “Run the PINGME.C Sample Program,” tests the TCP/IP portion of the board.
2.4.1 Troubleshooting
If Dynamic C cannot find the target system (error message
Detected."
• Check that the RCM3200 is powered correctly —
• Check both ends of the programming cable to ensure that they are firmly plugged into
• Ensure that the RCM3200 module is firmly and correctly installed in its connectors on
• Dynamic C uses the COM port or USB port specified during installation. Select a dif-
• If you get an error message when you plugged the programming cable into a USB port,
16
Board should be lit when the RCM3200 is mounted on the Prototyping Board and the AC
adapter is plugged in
the PC and the
ming port on the RCM3200 with the marked (colored) edge of the programming cable
towards pin 1 of the programming header.
the Prototyping Board.
ferent COM port within Dynamic C. From the
then select
Press
is unable to locate the target system, repeat the above steps until you locate the COM
port used by the programming cable.
you will have to install USB drivers. Drivers for Windows XP are available in the
Dynamic C
double-click
tems are available online at www.ftdichip.com/Drivers/VCP.htm.
NOTE: Dynamic C v. 9.60 or a later version is required if you are using an RCM3209 or
File
<Ctrl-Y>
an RCM3229 RabbitCore module.
folder. Press function key
menu to open the sample program
):
Communications
Drivers\Rabbit USB Programming Cable\WinXP_2K
DPInst.exe
PROG
to force Dynamic C to recompile the BIOS. If Dynamic C still reports it
tab. Click
menu. Click
.
connector, not the
and select “Use USB to Serial Converter” under the
OK
to install the USB drivers. Drivers for other operating sys-
OK
. Select another COM port from the list, then click
.
.
F9
to compile and run the program. The
on the “Compiler” tab in the Dynamic C
DIAG
PONG.C
Options
connector, is plugged in to the program-
the red power lamp on the Prototyping
, which is in the Dynamic C
menu, select
"No Rabbit Processor
Start
RabbitCore RCM3200
Project Options
menu. Select
STDIO
folder —
Options
OK
.
,