EMC1063-ACZL SMSC, EMC1063-ACZL Datasheet - Page 18

no-image

EMC1063-ACZL

Manufacturer Part Number
EMC1063-ACZL
Description
Board Mount Temperature Sensors Temp Snsr
Manufacturer
SMSC
Datasheet

Specifications of EMC1063-ACZL

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Revision 1.44 (04-14-08)
4.1
4.2
4.3
4.4
02h
03h Read,
09h Write
ADDR
ADDR
Status
REGISTER
Legacy Temperature Data Registers (00h, 23h, 01h, 10h, F8h,
Config
During Power on Reset (POR), the default values are stored in the registers. A POR is initiated when
power is first applied to the part and the voltage on the VDD supply surpasses the POR level as
specified in the electrical characteristics. Any reads to undefined registers will return 00h. Writes to
undefined registers will not have an effect.
The EMC1063 uses an interlock mechanism that will update the Low byte of a particular monitor when
the High Byte is read. This prevents changes in register content when the ADC updates between
successive reads.
F9h)
As shown in
is stored aligned to the left resulting in the High Byte containing temperature in 1°C steps and the Low
Byte containing fractions of a degree.
The Extended Format Temperature Registers store only the external diode temperatures in the
extended data format. This is because, due to the operating range limitations of the EMC1063, the
internal temperature could not benefit from the extended temperature range. Like the Legacy data
formatting, the data is stored in two registers per temperature channel.
The Status Register is a read only register and returns the operational status of the part. External diode
faults are indicated by bits 1 and 0. If either bit is set to ‘1’, then a diode fault has occurred. When a
diode fault occurs, the D1 or D2 status bit is set, but otherwise the data remains unchanged.
Bit 7 - Busy - indicates that the ADC is currently converting a temperature.
Bit 4 - HOTTER - during Hotter of Two mode, this bit indicates which of the external diode channels
is hotter. If this bit is ‘0’, then External Diode 1 is hotter or equal to External Diode 2. If this bit is ‘1’,
then External Diode 2 is hotter than External Diode 1. During normal operation, this bit will always read
a ‘0’.
Bit 1 - D2 - indicates that a diode fault has occurred on External Diode 2.
Bit 0 - D1 - indicates that a diode fault has occurred on External Diode 1.
Extended Format Temperature Registers (FAh-FDh)
Status Register - 02h
Configuration Register (03h Read, 09h Write)
REGISTER
Busy
Table
B7
-
B7
4.1, each temperature monitor has two data registers. The 11 bit temperature data
-
STANDBY
B6
Table 4.3 Configuration Register
B6
-
Table 4.2 Status Register
B5
DATASHEET
-
B5
HOTTER -
B4
18
-
B4
1°C Triple Temperature Sensor with Hotter of Two Zones
B3
-
B3
-
CR<2:0>
B2
B2
D2
B1
B1
D1
B0
B0
SMSC EMC1063
45h
DEFAULT
00h
DEFAULT
Datasheet

Related parts for EMC1063-ACZL