CS8900A-CQ3Z Cirrus Logic Inc, CS8900A-CQ3Z Datasheet - Page 103
CS8900A-CQ3Z
Manufacturer Part Number
CS8900A-CQ3Z
Description
IC LAN ETHERNET CTLR 3V 100LQFP
Manufacturer
Cirrus Logic Inc
Type
Single Chipr
Specifications of CS8900A-CQ3Z
Package / Case
100-LQFP
Controller Type
Ethernet Controller (IEEE 802.3)
Interface
ISA-BUS
Voltage - Supply
3V, 5V
Current - Supply
95mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Ethernet Connection Type
10BASE- 2 or 10BASE- 5 or 10BASE- F or 10BASE- T
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Controllers
Standard Supported
IEEE 802.3
Data Rate
10 Mbps
Supply Voltage (max)
6 V
Supply Voltage (min)
- 0.3 V
Supply Current (max)
+/- 10 mA
Maximum Operating Temperature
+ 70 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1163 - KIT EVAL FOR CS8900A
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
598-1127
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
CS8900A-CQ3Z
Manufacturer:
CIRRUS
Quantity:
16 572
Company:
Part Number:
CS8900A-CQ3Z
Manufacturer:
CIRRUSLOGIC92
Quantity:
1 900
Company:
Part Number:
CS8900A-CQ3Z
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8900A-CQ3Z
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS8900A-CQ3ZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS8900A-CQ3ZR
Manufacturer:
CIRRUS
Quantity:
20 000
DS271F5
5.6.8 Completing Transmission
When the CS8900A successfully completes
transmitting a frame, it sets the TxOK bit (Reg-
CS8900A
Crystal LAN™ Ethernet Controller
Exit: can't Issue command
Note: Issuing a command
at this point will cause
previous transmit frame
to be lost.
Figure 30. Transmit Operation in Polling Mode
CIRRUS LOGIC PRODUCT DATASHEET
Host Writes Transmit Command
Length to the TxLength Register
Enter Packet Transmit Process
Host Writes Transmit Frame
Yes
to the TxCMD Register
Host Reads the BusST
Exit Transmit Process
Register (Register 18)
CS8900A Commits
Transmits Frame
Transmit Frame
Transmit Frame
Buffer Space to
to CS8900A
Host Writes
Yes
CS8900A
pending?
No
TxNOW
TxCMD
bit = 1?
Rdy4
Is
No
ister 8, TxEvent, Bit 8). If the TxOKiE bit (Reg-
ister 7, TxCFG, bit 8) is set, the CS8900A
generates a corresponding interrupt.
Polling Loop
Transmit Request
103