AXA010A0M3Z Lineage Power, AXA010A0M3Z Datasheet

DC/DC Converters & Regulators 1.5Vout 10A SIP 10-14Vin

AXA010A0M3Z

Manufacturer Part Number
AXA010A0M3Z
Description
DC/DC Converters & Regulators 1.5Vout 10A SIP 10-14Vin
Manufacturer
Lineage Power
Series
AXA010r
Datasheet

Specifications of AXA010A0M3Z

Product
Non-Isolated / POL
Output Power
15 W
Input Voltage Range
10 V to 14 V
Number Of Outputs
1
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
10 A
Package / Case Size
SIP
Output Type
Non-Isolated
Output Voltage
1.5 V
Package / Case
SIP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
CC109106812
Data Sheet
September 30, 2009
Applications
Description
Austin Lynx
up to 10A of output current with full load efficiency of 93% at 3.3V output. These modules provide a precisely
regulated output voltage ranging from 1.2Vdc to 5.5Vdc over a wide range of input voltage (V
open-frame construction and small footprint enable designers to develop cost- and space-efficient solutions.
Standard features include remote On/Off, remote sense, output voltage adjustment, overcurrent and
overtemperature protection.
*
** ISO is a registered trademark of the International Organization of Standards
RoHS Compliant
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
Distributed power architectures
Intermediate bus voltage applications
Telecommunications equipment
Servers and storage applications
Networking equipment
TM
10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A Output Current
12V SIP (Single Inline Package) power modules are non-isolated DC-DC converters that can deliver
Austin Lynx
TM
12 V SIP Non-isolated Power Modules:
Features
Compliant to RoHS EU Directive 2002/95/EC (-Z
versions)
Compliant to ROHS EU Directive 2002/95/EC with
lead solder exemption (non-Z versions)
Delivers up to 10A of output current
High efficiency – 93% at 3.3V full load (V
Small size and low profile:
(2.00 in x 0.50 in x 0.320 in)
Low output ripple and noise
High Reliability:
Line Regulation: 0.3% (typical)
Load Regulation: 0.4% (typical)
Temperature Regulation: 0.4% (typical)
Remote On/Off
Remote Sense
Output overcurrent protection (non-latching)
Overtemperature protection
Wide operating temperature range (-40°C to 85°C)
UL* 60950-1Recognized, CSA
03 Certified, and VDE
Licensed
ISO** 9001 and ISO 14001 certified manufacturing
facilities
Calculated MTBF = 4.4 M hours at 25
50.8 mm x 12.7 mm x 8.10 mm
PDF name: austin_lynx_sip_12v_ds.pdf
Document No: DS03-084 ver. 1.22
0805:2001-12 (EN60950-1)
IN
= 10 – 14Vdc). Their
C22.2 No. 60950-1-
o
C Full-load
IN
= 12.0V)

Related parts for AXA010A0M3Z

AXA010A0M3Z Summary of contents

Page 1

Data Sheet September 30, 2009 Austin Lynx 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A Output Current RoHS Compliant Applications Distributed power architectures Intermediate bus voltage applications Telecommunications equipment Servers and storage applications Networking equipment Description TM Austin Lynx ...

Page 2

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, ...

Page 3

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Electrical Specifications (continued) Parameter Output Voltage Set-point ( =25°C) IN IN, min O O, max A Output ...

Page 4

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Electrical Specifications (continued) Parameter Dynamic Load Response (dIo/dt=2.5A/μ =25°C) IN IN, nom A Load Change from Io= 50% ...

Page 5

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Feature Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature Descriptions for additional information. ...

Page 6

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Characteristic Curves The following figures provide typical characteristics for the Austin Lynx ...

Page 7

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide typical characteristics for the Austin Lynx ...

Page 8

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide typical characteristics for the Austin Lynx TIME, t (10μs/div) Figure 13. Transient Response to Dynamic Load Change ...

Page 9

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Characteristic Curves (continued) The following figures provide thermal derating curves for the Austin Lynx ...

Page 10

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Test Configurations TO OSCILLOSCOPE L TEST 1μ 1000μF S Electrolytic 2x100μF E.S.R.<0.1Ω Tantalum @ 20°C 100kHz NOTE: Measure input reflected ripple ...

Page 11

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Design Considerations (continued) Output Filtering TM The Austin Lynx 12 V SIP module is designed for low output ripple voltage and will meet ...

Page 12

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Feature Description Remote On/Off TM The Austin Lynx 12V SIP power modules feature an On/Off pin for remote On/Off operation. If not using the ...

Page 13

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Feature Descriptions (continued) V (+) V (+) IN O ON/OFF TRIM GND Figure 29. Circuit configuration to trim-down output voltage using an external ...

Page 14

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Thermal Considerations Power modules operate in a variety of thermal environments; however, sufficient cooling should always be provided to help ensure reliable operation. Considerations ...

Page 15

Data Sheet March 29, 2006 10 – 14 Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Mechanical Outline Dimensions are in inches and (millimeters). Tolerances: x.xx in. ± 0.02 in. (x.x mm ± 0.5 mm) [unless otherwise indicated] x.xxx ...

Page 16

Data Sheet March 29, 2006 10 – 14Vdc input; 1.2Vdc to 5.5Vdc Output; 10A output current Recommended Pad Layout Dimensions are in inches and (millimeters). Tolerances: x.xx in. ± 0.02 in. (x.x mm ± 0.5 mm) [unless otherwise indicated] x.xxx ...

Page 17

... C. For Pb solder, the recommended pot temperature is 260 ° C, while the Pb-free solder pot is 270 ° C max. Not all RoHS-compliant through-hole products can be processed with paste-through-hole Pb or Pb-free reflow process. If additional information is needed, please consult with your Lineage Power technical representative for more details. LINEAGE POWER TM ...

Page 18

... AXA010A0M3 10 – 14Vdc AXA010A0Y3 10 – 14Vdc AXA010A0G3 10 – 14Vdc AXA010A0F3 10– 14Vdc AXA010A0A3 10 – 14Vdc AXA010A0P3Z 10 – 14Vdc AXA010A0M3Z 10 – 14Vdc AXA010A0Y3Z 10 – 14Vdc AXA010A0G3Z 10 – 14Vdc AXA010A0F3Z 10– 14Vdc AXA010A0A3Z 10 – 14Vdc -Z refers to RoHS-compliant versions World Wide Headquarters Lineage Power Corporation ...

Related keywords