S-8521A25MC-AXK-T2 Seiko Instruments, S-8521A25MC-AXK-T2 Datasheet - Page 16

DC/DC Switching Regulators 2.5V 60uA Step-Down

S-8521A25MC-AXK-T2

Manufacturer Part Number
S-8521A25MC-AXK-T2
Description
DC/DC Switching Regulators 2.5V 60uA Step-Down
Manufacturer
Seiko Instruments
Datasheet

Specifications of S-8521A25MC-AXK-T2

Output Voltage
2.5 V
Output Current
120 mA
Input Voltage
2.5 V to 10 V
Duty Cycle (max)
100 %
Switching Frequency
180 KHz
Mounting Style
SMD/SMT
Package / Case
SOT-23-5
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
16
STEP-DOWN, PWM CONTROL or PWM / PFM SWITCHABLE SWITCHING REGULATOR CONTROLLER
S-8520/8521 Series
1. Method for selecting series products
Selection of Products and External Parts
1. 1 Control systems
1. 2 Oscillation frequencies
The S-8520/8521 Series is classified into 12 types, according to the control systems (PWM control and PWM / PFM
switching control), the different oscillation frequencies, and set-up of an overload protection circuit. Please select
the type for your application according to the following features.
Two different control systems are available: PWM control system (S-8520 Series) and PWM / PFM switching
control system (S-8521 Series).
For applications for which the load current greatly differs between standby and operation, if the efficiency during
standby is important, applying the PWM/PFM switching system (S-8321 Series) realizes high efficiency during
standby.
For applications for which switching noise is critical, applying the PWM control system (S-8320 Series) whereby
switching frequency does not change due to load current allows the ripple voltage to be easily suppressed by
using a filter.
Either oscillation frequency, 180 kHz (A and B types), 60 kHz (C and D types), or 300 kHz (E and F types), can
be selected.
The A, B, E and F types have high oscillation frequency, how ripple voltage and excellent transient response
characteristics. A small inductance can be used for these types because the peak current is low when inducing
the same load current. Use of small output capacitors is effective for downsizing devices.
The C and D types, whereby lower oscillation frequency realizes smaller self-consumption current, are highly
efficient under light loads. In particular, the D type, when combined with a PWM/PFM switching control system,
drastically improves the operation efficiency when the output load current is approximately 100 mA.
Seiko Instruments Inc.
Rev.9.0
_00