ADM3488EARZ Analog Devices Inc, ADM3488EARZ Datasheet - Page 15

IC TXRX ESD RS-485 3.3V 8-SOIC

ADM3488EARZ

Manufacturer Part Number
ADM3488EARZ
Description
IC TXRX ESD RS-485 3.3V 8-SOIC
Manufacturer
Analog Devices Inc
Type
Transceiverr
Datasheet

Specifications of ADM3488EARZ

Number Of Drivers/receivers
1/1
Protocol
RS422, RS485
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Device Type
Differential
No. Of Drivers
1
Supply Voltage Range
3V To 3.6V
Driver Case Style
SOIC
No. Of Pins
8
Operating Temperature Range
-40°C To +85°C
Svhc
No SVHC (18-Jun-2010)
Package /
RoHS Compliant
Interface Type
RS422, RS485
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM3488EARZ
Manufacturer:
ADI
Quantity:
12 000
Part Number:
ADM3488EARZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
±15 kV ESD PROTECTION
Two coupling methods are used for ESD testing: con-
tact discharge and air-gap discharge. Contact discharge
calls for a direct connection to the unit being tested. Air-
gap discharge uses a higher test voltage but does not make
direct contact with the test unit. With air-gap discharge,
the discharge gun is moved toward the unit under test,
developing an arc across the air gap, therefore the term air-
gap discharge. This method is influenced by humidity,
temperature, barometric pressure, distance, and rate of
closure of the discharge gun. The contact discharge
method, while less realistic, is more repeatable and is
gaining acceptance and preference over the air-
gap method.
Although very little energy is contained within an ESD pulse,
the extremely fast rise time, coupled with high voltages, can
cause failures in unprotected semiconductors. Catastrophic
destruction can occur immediately as a result of arcing or
heating. Even if catastrophic failure does not occur immediately,
the device can suffer from parametric degradation that can
result in degraded performance. The cumulative effects of
continuous exposure can eventually lead to complete failure.
Input/output lines are particularly vulnerable to ESD damage.
Simply touching or connecting an input/output cable can result
in a static discharge that can damage or completely destroy the
interface product connected to the input/output port. It is
extremely important, therefore, to have high levels of ESD
protection on the input/output lines.
The ESD discharge can induce latch-up in the device under test,
so it is important that ESD testing on the input/output pins be
carried out while device power is applied. This type of testing is
more representative of a real-world input/output discharge,
which occurs when the equipment is operating normally.
The transmitter outputs and receiver inputs of the ADM34xxE
family are characterized for protection to a ±15 kV limit using
the human body model.
HUMAN BODY MODEL
Figure 30 shows the human body model and the current wave-
form it generates when discharged into a low impedance. This
model consists of a 100 pF capacitor charged to the ESD voltage
of interest, which is then discharged into the test device
through a 1.5 kΩ resistor.
ADM3483E/ADM3486E/ADM3488E/ADM3490E/ADM3491E
Rev. A | Page 15 of 20
TYPICAL APPLICATIONS
The ADM3483E/ADM3486E/ADM3491E transceivers are
designed for bidirectional data communications on multipoint
bus transmission lines. The ADM3488E/ADM3490E full-duplex
transceiver is designed to be used in a daisy-chain network
topology or in a point-to-point application (see Figure 32). The
ADM3483E/ADM3486E are half-duplex RS-485 transceivers
that can be used in a multidrop bus configuration, as shown in
Figure 31. The ADM3488E/ADM3490E/ADM3491E can also
be used as a line repeater, for use with cable lengths longer than
4000 feet, as shown in Figure 34. To minimize reflections, the
line must be terminated at both ends in its characteristic
impedance, and stub lengths off the main line should be kept as
short as possible.
36.8%
100%
90%
10%
GENERATOR
Figure 30. Human Body Model and Current Waveform
VOLTAGE
HIGH
t
RL
HUMAN BODY MODEL
ESD ASSOC. STD 55.1
ESD TEST METHOD
R1
t
DL
C1
1.5kΩ
R2
R2
100pF
C1
DEVICE
UNDER
TEST
TIME
t