H5CX-A11-N-AC100/240 Omron Automation, H5CX-A11-N-AC100/240 Datasheet - Page 12

no-image

H5CX-A11-N-AC100/240

Manufacturer Part Number
H5CX-A11-N-AC100/240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 11 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A11-N-AC100/240

Brand/series
H5CX
Connection Type
11 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
12
H5CX-A@-N/-L@-N
Accessories (Order Separately)
Front Panel (Replacement Part)
You can change the color of the front panel when mounting the Timer.
The Timer is shipped with a black (N1.5) Front Panel.
Y92P-CXT4S
Cover for Timer with 4 Digits
White (5Y9.2/0.5)
Y92P-CXT4G
Cover for Timer with 4 Digits
Light gray (5Y7/1)
Y92P-CXT4B
Cover for Timer with 4 Digits
Black (N1.5)
Replacement Method
Tabs
Note:
Depending on the operating environment, the condition of
resin products may deteriorate, and may shrink or become
harder. Therefore, it is recommended that resin products are
replaced regularly.
Grooves
The Front Panel is attached to
the Terminal with tabs in four
locations. To remove the Front
Panel, open the tabs and pull the
Front Panel forward.
To attach the Front Panel, press
it onto the Timer so that all four
tabs lodge into the groves on the
body of the Timer.
Soft Cover
Y92A-48F1
Protecting the Timer in Environments Subject to Oil
Flush Mounting Adapter
Y92F-30
Order the Flush
Mounting Adapter
separately if it is
lost or damaged.
Note: A Flush
Waterproof Packing
Y92S-29
Note: The
The Waterproof Packing will deteriorate, harden, and shrink
depending on the application environment. To ensure maintaining the
IP@6, UL Type 4X waterproof level, periodically replace the
Waterproof Packing. The periodic replacement period will depend on
the application environment. You must confirm the proper
replacement period. Use 1 year or less as a guideline. If the
Waterproof Packing is not replaced periodically, the waterproof level
will not be maintained.
It is not necessary to mount the Waterproof Packing if waterproof
construction is not required.
The H5CX's panel surface is water-resistive (IP@6, UL Type 4X)
and so even if drops of water penetrate the gaps between the keys,
there will be no adverse effect on internal circuits. If, however, there
is a possibility of oil being present on the operator's hands, use the
Soft Cover. The Soft Cover ensures protection equivalent to IP54
against oil. Do not, however, use the H5CX in locations where it
would come in direct contact with oil.
Mounting
Adapter is
included with
models with
screw
terminals.
Waterproof
Packing is
included with
models with
screw
terminals.
Y92F-45
Use this Adapter
to install the
Timer in a cutout
previously made
for a DIN 72 x 72
mm device
(panel cutout:
68 x 68 mm).
Order the Waterproof Packing
separately if it is lost or damaged.
The Waterproof Packing can be used
to achieve IP66 protection.
Hard Cover
Y92A-48