H5CX-A11-N-AC100/240 Omron Automation, H5CX-A11-N-AC100/240 Datasheet - Page 6

no-image

H5CX-A11-N-AC100/240

Manufacturer Part Number
H5CX-A11-N-AC100/240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 11 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A11-N-AC100/240

Brand/series
H5CX
Connection Type
11 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
6
H5CX-A@-N/-L@-N
Characteristics
* Refer to Life-test Curve.
Accuracy of operating time
and setting error (including
temperature and voltage
influences)
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration
resistance
Shock
resistance
Life
expectancy
Weight
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
Power-ON start: ±0.01% ±50 ms max. (See note 1.)
Signal start: ±0.005%±0.03 ms max. (See note 1.)
Signal start for transistor output model: ±0.005%±3 ms max. (See note
1 and 2.)
If the set value is within the sensor waiting time at startup the control
output of the H5CX will not turn ON until the sensor waiting time passes.
Note: 1. The values are based on the set value.
100 MΩ min. (at 500 VDC) between current-carrying terminal and
exposed non-current-carrying metal parts, and between non-continuous
contacts
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
non-current-carrying metal parts
2,000 VAC, 50/60 Hz for 1 min between power supply and input circuits
for H5CX-A11-N/-A11S-N
1,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits for H5CX-@SD-N
2,000 VAC, 50/60 Hz for 1 min between control output, power supply,
and input circuits for other models
1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts
3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12
to 24 VDC
4.5 kV (between current-carrying terminal and exposed non-current-
carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC
±1.5 kV (between power terminals) and ±600 V (between input
terminals), square-wave noise by noise simulator (pulse width: 100 ns/
1 µs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
10 to 55 Hz with 0.75-mm single amplitude each in three directions for
2 h each
10 to 55 Hz with 0.35-mm single amplitude each in three directions for
10 min each
300 m/s
100 m/s
10,000,000 operations min. (under no load at 18,000 operations/h and
ambient temperature of 23
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800
operations/h and ambient temperature of 23
Approx. 115 g (Timer only)
2. The value is applied for a minimum pulse width of 1 ms.
2
2
in three directions, three cycles
in three directions, three cycles
°
C)
°
C)
*
Life-test Curve (Reference
Values)
A maximum current of 0.15 A can be switched at
125 VDC (cosφ =1) and a maximum current of 0.1
A can be switched if L/R is 7 ms. In both cases, a
life of 100,000 operations can be expected.
1,000
500
100
50
10
0
AC250V cos =0.4
1
DC30V L/R=7ms
2
3
AC250V/DC30V
cos =1
4
Load current (A)
5