H5CX-A11-N-AC100/240 Omron Automation, H5CX-A11-N-AC100/240 Datasheet - Page 30

no-image

H5CX-A11-N-AC100/240

Manufacturer Part Number
H5CX-A11-N-AC100/240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; Socket Mnt; 11 Pin
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A11-N-AC100/240

Brand/series
H5CX
Connection Type
11 Pin Socket
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 62.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush, Surface or Din Rail
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
30
H5CX-A@-N/-L@-N
Twin Timer
Models with Instantaneous Contact Outputs
Note: H5CX-L8E@-N Precautions
Instantaneous
Instantaneous
Mode ton-1: Flicker ON start 2 (Timer does not reset when power comes ON.)
Basic operation
* Start signal input is disabled during timing.
Timing starts when the start signal goes ON.
The status of the control output is reversed when time is
up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Note: Normal output operation will not be possible if
Mode toff: Flicker OFF start 1 (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Mode ton: Flicker ON start 1 (Timer resets when power comes ON.)
Basic operation
The Timer starts when the power comes ON or when
the reset input goes OFF.
Note: Normal output operation will not be possible if
Start signal
Time-limit
Time-limit
Power
Power
output
output
output
output
Set the Timer’s set value before using the Timer in a self-holding circuit.
Output
Power
the set time is too short.
Set the value to at least 100 ms (contact output
type).
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
the set time is too short.
Set the ON time and OFF time to at least 100
ms.
input
*
Ton time
Toff time
Timing
ON
Toff time
Ton time
Timing
OFF
Toff time
Ton time
Timing
ON
(a + b = OFF time)
Toff time
a
Ton time
b
Detailed operation
Detailed operation
Detailed operation
Instantaneous
Instantaneous
Instantaneous
Instantaneous
contacts, NO
contacts, NO
contacts, NO
contacts, NO
contacts, NC
contacts, NC
contacts, NC
contacts, NC
Control output
Reset Key
Reset Key
Time-limit
Time-limit
Time-limit
Time-limit
UP
DOWN
Start signal
Power
Power
OFF time
OFF time
ON time
ON time
Power
Reset
Gate
0
0
t-a
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
t-b
t-on = ON time, t-off = OFF time, Rt = Reset time (0.1 s min.), t – a < t-off and t – b < t-on
(Indicates the time is less than the set time.)
t-off
t-on
t-on
t-off
t-off
t-on
t-b
t-a
Rt
Rt
t-off
t-on
t-on
t-off
t-off
t-on
t-b
t-a
t-b
t-a
Rt
Rt
t-a
t-b