VQZ115-5L1-N3 SMC Corporation, VQZ115-5L1-N3 Datasheet - Page 20

no-image

VQZ115-5L1-N3

Manufacturer Part Number
VQZ115-5L1-N3
Description
Solenoid Valve, 3 port, body ported, 24VDC, L plug conn w/.3m lead, 5/32 fitting
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQZ115-5L1-N3

Brand/series
VQZ Series
Configuration
Body Ported
Number Of Ports
3
Primary Type
Solenoid Valve
Size, Port
5⁄32"
Voltage, Coil
24 VDC
Operating Pressure Range
15-100 PSI (30-100 PSI For Three Position Valves)
Base Mounted
Plug Lead Unit
17
KR
R
Symbol
K
Note 1, 2)
Nil
Note 1)
Note 1, 2)
1
Note 1) Option
Note 2) For details on external pilot type, refer to page 32.
Note 3) For AC specification power consumption, refer to
Use standard (DC) specification for
continuous duty.
VQZ100 body width 10 mm
Standard
High pressure type
External pilot type
High pressure/External pilot type
page 19.
Caution
Type of actuation
VQZ 1 1 5
Specifications
1
Series
N.C.
Series
3 Port Solenoid Valve
Single Unit
5
(P)
Body type
Base mounted
1
(A)
2
3
(R)
Function
(0.35 W)
(0.9 W)
(0.9 W)
DC
VQZ100
Note 3)
AC
VQZ100/200/300
/ How to Order Valve
5 M
Coil voltage
1
2
3
4
5
6
100 VAC (50/60 Hz)
200 VAC (50/60 Hz)
110 VAC [115 VAC] (50/60 Hz)
220 VAC [230 VAC] (50/60 Hz)
24 VDC
12 VDC
G: Grommet
Electrical entry
(DC speci-
fication)
Note) Standard lead wire length: 300 mm
Nil: Non-locking
Manual override
1
push type
L: L-type plug
With light/
surge voltage
suppressor
connector
with lead
wire
01
Note) For optional thread type,
B: Locking type
Port size [2(A) port]
CP
01
(Tool required)
refer to page 32.
LO: L-type plug
With light/
surge voltage
suppressor
Without sub-plate
Rc 1/8
Note) For CE compliant
connector
without
connector
CE compliant
Nil
Note) For sub-plate part no., refer to page 33.
Q
models, DC-type
only.
CE marked
M: M-type plug
With light/
surge voltage
suppressor
connector
with lead
wire
MO: M-type plug
With light/
surge voltage
suppressor
[Option]
connector
without
connector

Related parts for VQZ115-5L1-N3