DNC-T2101-B10 NCC, DNC-T2101-B10 Datasheet - Page 2

no-image

DNC-T2101-B10

Manufacturer Part Number
DNC-T2101-B10
Description
Dust Collector; Inetermittent shaker control, 120 delay, 105 to 135 VAC
Manufacturer
NCC
Datasheet
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
Model DNC-2101-010
Model DNC-2101-020
Field Wiring Diagram
.312 DIA.
4 HOLES
.25
Shake Time
Adjust
(4250-1 10/92)
3A
Control Power On
Load On
6.0
4.0
4 HOLES
.25 DIA.
120
VAC
DUST COLLECTOR CONTROLS
L1
L2
1.8
5.125
4.625
L1 L2
1 2 3 4
T2101
sec. 180
1.0
Terminal
Block
1
3
2
4
#6 screw typ.
L1
L2
On
Off
Metal Chassis
F
Fan
Start/Stop
Switch
Contactor
Fan
Coil
2.125 Max.
N.O.
Aux.
4.875
.625
S
Shaker
Contactor
Coil
4-3