N9010A-526 Agilent Technologies Test Equipment, N9010A-526 Datasheet - Page 3

no-image

N9010A-526

Manufacturer Part Number
N9010A-526
Description
EXA SIGNAL ANALYZER 26 GHZ
Manufacturer
Agilent Technologies Test Equipment
Type
Networkr
Datasheet

Specifications of N9010A-526

Frequency
26 GHz
Lead Free Status / Rohs Status
RoHS Exempt Product
Definitions and Conditions
Specifi cations describe the performance
of parameters covered by the product
warranty and apply over 5 to 50 °C unless
otherwise noted. 95th percentile values
indicate the breadth of the population
(≈2σ) of performance tolerances
expected to be met in 95 percent of the
cases with a 95 percent confi dence,
for any ambient temperature in the
range of 20 to 30 °C. In addition to the
statistical observations of a sample
of instruments, these values include the
effects of the uncertainties of external
calibration references. These values
are not warranted. These values are
updated occasionally if a signifi cant
change in the statistically observed
behavior of production instruments is
observed. Typical describes additional
product performance information that
is not covered by the product warranty.
It is performance beyond specifi cations
that 80 percent of the units exhibit
with a 95 percent confi dence level over
the temperature range 20 to 30 °C.
Typical performance does not include
measurement uncertainty. Nominal
values indicate expected performance,
or describe product performance that
is useful in the application of the
product, but is not covered by the
product warranty.
The analyzer will meet its
specifi cations when:
• The analyzer is within its calibration
• Under auto couple control, except
• For signal frequencies < 20 MHz,
• The analyzer has been stored at
• The analyzer has been turned on at
cycle.
that Auto Sweep Time Rules = Accy.
DC coupling applied.
an ambient temperature within
the allowed operating range for at
least two hours before being turned
on, if it had previously been stored
at a temperature range inside the
allowed storage range but outside
the allowed operating range.
least 30 minutes with Auto Align
set to normal, or if Auto Align is set
to off or partial, alignments must
have been run recently enough to
prevent an Alert message. If the
Alert condition is changed from
Time and Temperature to one of
the disabled duration choices,
the analyzer may fail to meet
specifi cations without informing
the user.
This EXA signal analyzer data
sheet is a summary of the complete
specifi cations and conditions, which
are available in the EXA Signal
Analyzer Specifi cation Guide. The EXA
Signal Analyzer Specifi cation Guide
can be obtained on the web at:
www.agilent.com/find/exa_manuals.
3