ADM560JRS Analog Devices Inc, ADM560JRS Datasheet - Page 8

IC TXRX RS232 4:5 3.3V LP 28SSOP

ADM560JRS

Manufacturer Part Number
ADM560JRS
Description
IC TXRX RS232 4:5 3.3V LP 28SSOP
Manufacturer
Analog Devices Inc
Type
Transceiverr
Datasheet

Specifications of ADM560JRS

Rohs Status
RoHS non-compliant
Number Of Drivers/receivers
4/5
Protocol
RS232
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Package / Case
28-SSOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM560JRS
Manufacturer:
ROHM
Quantity:
3 000
Part Number:
ADM560JRSZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADM560JRSZ-REEL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADM560/ADM561
THEORY OF OPERATION
The ADM560/ADM561 are RS-232 transmission line drivers/
receivers, and operate from a single +3.3 V supply. This is achieved
by integrating step-up voltage converters and level shifting trans-
mitters and receivers onto the same chip. CMOS technology is
used to keep the power dissipation at an absolute minimum.
The ADM560/ADM561 are a modification, enhancement, and
improvement to the ADM241L family and its derivatives thereof.
These devices are essentially plug-in compatible and do not
have materially different applications.
The ADM560/ADM561 contain an internal voltage doubler
and a voltage inverter that generates ±6.6 V from the +3.3 V
input. Four external 1 μF capacitors are required for the inter-
nal voltage converters.
CIRCUIT DESCRIPTION
The internal circuitry consists of three main sections. These are
as follows:
Charge Pump DC-to-DC Voltage Converter
The charge pump voltage converter consists of an oscillator and
a switching matrix. The converter generates a ±6.6 V supply from
the input +3.3 V level. This is done in two stages using a switched
capacitor technique (see Figure 11 and Figure 12). First, the
+3.3 V input supply is doubled to +6.6 V using Capacitor C1
as the charge storage element. The +6.6 V level is then inverted
to generate −6.6 V using Capacitor C2 as the storage element.
Capacitor C3 and Capacitor C4 are used to reduce the output
ripple. Their values are not critical and can be reduced if higher
levels of ripple are acceptable. The C1 and C2 charge pump capac-
itors can also be reduced at the expense of the higher output
impedance on the V+ and V− supplies.
The V+ and V− supplies are also used to power external
circuitry if the current requirements are small.
A charge pump voltage converter.
3 V logic to EIA-232 transmitters.
EIA-232 to 3 V logic receivers.
Rev. B | Page 8 of 12
Transmitter (Driver) Section
The drivers convert 3 V or 5 V logic input levels into EIA-232
output levels. With V
the output voltage swing is typically ±5.5 V.
DOUBLER
Unused inputs can be left unconnected as an internal 400 kΩ
pull-up resistor pulls them high forcing the outputs into a low
state. The input pull-up resistors typically source 8 μA when
grounded, so connect unused inputs to V
ted in order to minimize power consumption.
Receiver Section
The receivers are inverting level shifters; they accept EIA-232
input levels and translate them into 3 V logic output levels. The
inputs have internal 5 kΩ pull-down resistors to ground and are
also protected against overvoltages of up to ±25 V. The guaranteed
switching thresholds are 0.4 V minimum and 2.4 V maximum.
Unconnected inputs are pulled to 0 V by the internal 5 kΩ pull-
down resistor. This results in a Logic 1 output level for unconnected
inputs or for inputs connected to GND.
The receivers have a Schmitt trigger input with a hysteresis level
of 0.3 V. This ensures error-free reception for both noisy inputs
and for inputs with slow transition times.
ENABLE AND SHUTDOWN
Table 4 shows the truth table for the enable and shutdown
control signals. When disabled all receivers are placed in a
high impedance state. In shutdown, all transmitters are disa-
bled and all receivers on the ADM561 are disabled. On the
ADM560, Receiver R4 and Receiver R5 remain enabled in
shutdown.
VOLTAGE
OSCILLATOR
FROM
INTERNAL
GND
V
CC
OSCILLATOR
INTERNAL
GND
V+
Figure 12. Charge Pump Voltage Inverted Operation
Figure 11. Charge Pump Voltage Double Operation
S1
S2
S1
S2
CC
C1
= +3.3 V and driving an EIA-232 load,
C2
+
+
S3
S4
S3
S4
CC
or leave unconnec-
C3
C4
+
+
GND
V– = – (V+)
V+ = 2V
V
CC
CC

Related parts for ADM560JRS