PEB3086FV14XP Lantiq, PEB3086FV14XP Datasheet - Page 228

PEB3086FV14XP

Manufacturer Part Number
PEB3086FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3086FV14XP

Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
4.6.15
RFIFOB
A read access to this register gives access to the “current” FIFO location selected by an
internal pointer which is automatically incremented after each read access.
The RFIFOB contains up to 128 bytes of received data.
After an ISTAB.RPF interrupt, a complete data block is available. The block size can be
8 or 16 bytes depending on the EXMB.RFBS setting.
After an ISTAB.RME interrupt, the number of received bytes can be obtained by reading
the RBCLB register.
4.6.16
XFIFOB
A write access to this register gives access to the “current” FIFO location selected by an
internal pointer which is automatically incremented after each write access.
The total XFIFO size is 128 byte and data blocks with up to 32 bytes of transmit data can
be written to the XFIFOB following an ISTAB.XPR interrupt.
Data Sheet
7
7
RFIFOB - Receive FIFO B-Channel
XFIFOB - Transmit FIFO B-Channel
Transmit data
Receive data
228
Detailed Register Description
0
0
PEB 3086
2003-01-30
ISAC-SX
WR (7A)
RD (7A)

Related parts for PEB3086FV14XP