Table 12
U4H
U4
U5
SP
3.5.8
For the awake process two signals are defined ’U1W’ and ’U2W’. Depending on the call
direction (up-, downstream) U1W and U2W are interpreted as awake or acknowledge
signals (see figures below).
Figure 14
Data Sheet
NT
LT
Awake Protocol
INFO U2W
2.133 ms
U4H requires the NT to go to the ’Transparent’ state. On detecting U4H the
NT stops sending signal U3 and informs the S-transceiver or a layer-2
device via the IOM
The M-channel on U may be used to transfer loop commands.
U4 transports operational data on B and D channels. The M-channel on U
may be used to transfer loop commands.
U5 transports operational data on B and D channels. The M-channel on U
may be used to transfer code error indications.
The DFE-T V2.2 sends periodically single pulses once per millisecond on
the U-interface. The test mode can be used for pulse mask
measurements.
4B3T Signal Elements (cont’d)
Awake Procedure Initiated by the LT
INFO U1W
2.133 ms
12 ms
®
-2 interface.
13 ms
7 ms
53
INFO U2
Functional Description
INFO U1A