DC1540A Linear Technology, DC1540A Datasheet - Page 37

no-image

DC1540A

Manufacturer Part Number
DC1540A
Description
LTC2978 Demoboard (includes DC1360A + DC1361A), Requires DC1613A
Manufacturer
Linear Technology
Series
-r
Datasheets

Specifications of DC1540A

Design Resources
DC1540 Design File
Main Purpose
Power Management, Power Supply Supervisor/Tracker/Sequencer
Embedded
No
Utilized Ic / Part
LTC2978
Primary Attributes
Voltage Detector & Supervisor
Secondary Attributes
-
Kit Application Type
Power Management
Application Sub Type
Power Supply Controller
Features
Demonstration System For The LTC2978 Octal I2C / SMBus / PMBus Power Supply Monitor & Controller
Lead Free Status / Rohs Status
Not applicable / Not applicable
operaTion
MFR_FAULTB00_PROPAGATE, MFR_FAULTB01_
PROPAGATE, MFR_FAULTB10_PROPAGATE and
MFR_FAULTB11_PROPAGATE
These manufacturer specific commands enable channels
that have faulted off to propagate that state to the ap-
propriate fault pin. There are two zones in the LTC2978.
In zone 0, faulted off states for channels 0 through 3 can
be propagated to FAULT00 or FAULT01. In zone 1, faulted
off states for channels 4 through 7 can be propagated to
FAULT10 or FAULT11. See Figure 13.
MFR_FAULTB00_PROPAGATE Data Contents—Fault Zone 0
(Pages 0-3)
MFR_FAULTB01_PROPAGATE Data Contents—Fault Zone 0
(Pages 0-3)
BIT(S) SYMBOL
b[7:1] Reserved
b[0]
BIT(S) SYMBOL
b[7:1] Reserved
b[0]
Mfr_faultb00_propagate
Mfr_faultb01_propagate
OPERATION
Don’t care. Always returns 0.
Enable fault propagation.
0: FAULTB00 will not be affected if
a fault is declared.
1: FAULTB00 will be asserted low
if a fault is declared.
OPERATION
Don’t care. Always returns 0.
Enable fault propagation.
0: FAULTB01 will not be affected if
a fault is declared.
1: FAULTB01 will be asserted low
if a fault is declared.
MFR_FAULTB10_PROPAGATE Data Contents—Fault Zone 1
(Pages 4-7)
MFR_FAULTB11_PROPAGATE Data Contents—Fault Zone 1
(Pages 4-7)
BIT(S) SYMBOL
b[7:1] Reserved
b[0]
BIT(S) SYMBOL
b[7:1] Reserved
b[0]
Mfr_faultb10_propagate
Mfr_faultb11_propagate
OPERATION
Don’t care. Always returns 0.
Enable fault propagation.
0: FAULTB10 will not be affected if
a fault is declared.
1: FAULTB10 will be asserted low
if a fault is declared.
OPERATION
Don’t care. Always returns 0.
Enable fault propagation.
0: FAULTB11 will not be affected if
a fault is declared.
1: FAULTB11 will be asserted low
if a fault is declared.
LTC2978

2978fa

Related parts for DC1540A