ZMOTIONS200ZCOG Zilog, ZMOTIONS200ZCOG Datasheet

no-image

ZMOTIONS200ZCOG

Manufacturer Part Number
ZMOTIONS200ZCOG
Description
KIT DEV ZMOTION MODULE
Manufacturer
Zilog
Series
ZMOTION™r

Specifications of ZMOTIONS200ZCOG

Sensor Type
Motion, PIR (Pyroelectric Infrared)
Sensing Range
-
Interface
USB/Serial
Sensitivity
-
Voltage - Supply
-
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
ZMOT1AHH
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
269-4823
ZMOTIONS200ZCOG
ZMOTION
Intrusion
Detection Development
Kit
User Manual
UM023301-0411
Copyright ©2011 Zilog Inc. All rights reserved.
www.zilog.com

Related parts for ZMOTIONS200ZCOG

ZMOTIONS200ZCOG Summary of contents

Page 1

... ZMOTIONS200ZCOG ZMOTION Detection Development Kit User Manual UM023301-0411 Copyright ©2011 Zilog Inc. All rights reserved. www.zilog.com ™ Intrusion ...

Page 2

... DEVICES, OR TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. ZMOTION, Z8 Encore! and Z8 Encore! XP are registered trademarks of Zilog Inc. All other product or service names are the property of their respective owners. UM023301-0411 ™ ...

Page 3

Revision History Each instance in the table below reflects a change to this document from its previous edition. For more details, refer to the corresponding pages and appropriate links in the table below. Revision Date Level April 2011 01 UM023301-0411 ...

Page 4

Table of Contents Revision History ...

Page 5

... The Z8FS021 MCU, a prominent member of the ZMOTION Family, combines the programmability and rich peripheral set of Zilog’s Flash Z8 Encore! XP algorithms to provide the functions necessary for PIR motion detection applications. These motion detection algorithms comprise Zilog’ ...

Page 6

... ZMOTION Family Technical Documentation (on CD-ROM) – ZMOTION Intrusion Detection Product Specification (PS0288) – ZMOTION Intrusion Detection Product Brief (PB0230) 1. Zilog recommends using only the power supply provided in the ZMOTION Intrusion Detection Development Kit. UM023301-0411 ™ ZMOTION Intrusion Detection Development Kit ...

Page 7

ZMOTION Detection and Control Product Specification (PS0285) – ZMOTION Detection and Control Product Brief (PB0225) – ZMOTION Detection Module Product Specification (PS0284) – ZMOTION Detection Module Product Brief (PB0223) – ZMOTION Lens and Pyroelectric Sensor Product Specification (PS0286) – ...

Page 8

Three 1.2" Intrusion Detection lenses 1.2" Lens Holder Figure 1. ZMOTION Intrusion Detection Development Kit Contents Sample code files are included on the ZMOTION Sample Applications CD, and are located in the UM023301-0411 ™ ZMOTION Intrusion Detection Development Kit ZMOTION ...

Page 9

System Requirements An IBM PC (or compatible computer) with the following minimum con- figurations is required: • Microsoft Windows 7, Windows XP Professional SP1, Windows 2000 SP3, Windows NT 4.0 SP6 • Pentium II/233 MHz processor or higher up to ...

Page 10

... ZMOTION Intrusion Detection Development Board Zilog’s ZMOTION Intrusion Detection Development Board is a develop- ment and prototyping platform for the ZMOTION Intrusion Detection sil- icon and software as well as for lens/pyroelectric sensor/silicon and software bundled solutions. The Board provides the user with a tool to evaluate the many features of ZMOTION PIR technology, as well as the actual performance of each lens and pyro combination ...

Page 11

... V–3.6 V operating voltage with 5 V tolerant inputs MCU Features The Z8FS021 ZMOTION Intrusion Detection MCU combines the pro- grammability and rich peripheral set of Zilog’s Flash Z8 Encore! XP Family of MCUs with built-in motion detection software algorithms to provide the functions necessary for PIR motion detection applications. ...

Page 12

... I/O pins depending upon package • 2 3.6 V operating voltage with extended operating temperature range –40° +105° C • Zilog PIR technology controlled and monitored via software API reg- isters • Selection capability from an assortment of lenses and pyroelectric sensors to best fit your application • ...

Page 13

... These applications also demonstrate the flexibility, and superior performance of Zilog’s PIR motion detection technology. Please refer to the ZMOTION Lens and Pyroelectric Sensor Product Specification (PS0286) for part-specific details about the individual lenses and pyroelectric sensors ...

Page 14

... As new lens types are added to the ZMOTION family, an associ- ated lens configuration file is made available on the Zilog website. Table 2 lists additional project features that can be modified or enabled in and main ...

Page 15

When motion is detected, the LED is turned ON for 1 second ( ). A serial terminal program such as HyperTerminal can be used layTime to view the detection messages from the ZMOTION Development Board (see Figure 3). In the ...

Page 16

... Installing ZDS II and the USB Smart Cable Observe the following the steps to install Zilog Developer Studio (ZDS II) and its associated documentation. 1. Insert the ZDS II CD into the CD-ROM drive. The DemoShield installer launches automatically. If DemoShield does not launch automatically, open Windows Explorer, browse to your CD-ROM drive and double-click 2 ...

Page 17

Search dialog and continue to Step the Windows Start menu’s Device Manager will appear in the Start menu’s resulting Program list; click to launch it the Device Manager, ...

Page 18

... Observe the following steps to install the USB Smart Cable for Windows XP systems. 1. Connect the Zilog USB device to the host PC. The Hardware Zilog USB device for the first time. If prompted to connect to Windows Update, select 2. Select [Install from a list or specific location (Advanced)] click ...

Page 19

... After you find the appropriate driver, click 6. Click Finish Windows 2000 Observe the following steps to install the USB Smart Cable for Windows 2000 systems. 1. Connect the Zilog USB device to the host PC. The Hardware Zilog USB device for the first time. 2. After the . Next 3 ...

Page 20

The power to the development board must be disconnected or turned Caution: OFF before connecting or disconnecting the USB Smart Cable. 1. Attach one end of the six-conductor ribbon cable (included) to the USB Smart Cable six-pin DBG connector, as ...

Page 21

Installing the FTDI USB to Serial Driver Observe the following steps to install the FTDI USB to Serial Driver. 1. Make sure that the USB cable is not plugged into the ZMOTION Development Board the CDROM, double-click the ...

Page 22

Read Only Deselect the changes to this and the other subfolders when prompted. In this example, we reference the however, the steps that follow will apply to any additional project. Note: At this point you should have loaded ...

Page 23

Figure 5. Building the ZMOTION_Intrusion_Demo project in ZDS II Figure 6. The Location of the Rebuild All Icon UM023301-0411 ™ ZMOTION Intrusion Detection Development Kit The Rebuild All icon ZMOTION Intrusion Detection Development Board User Manual 19 ...

Page 24

Make sure that the ZMOTION Development Board is powered OFF, then connect the USB Smart Cable (Debugger) to P2, as described above. 5. Apply power to the Development Board by plugging in the USB cable and setting SW1 to ...

Page 25

Figure 8. ZDS II’s Debug Output Window for the ZMOTION_Basic project 7. Click the (LED2) will be ON initially until the pyroelectric sensor stabilizes – a period that can take seconds. After it has stabilized, (LED2) turns ...

Page 26

Making Changes to the ZMOTION_Intrusion_Demo Project To change the duration of the LED on time, observe the following proce- dure. 1. Change the following line in the unsigned int cMDDelayTime = DELAY_1SEC; 2. Change the line as follows to select ...

Page 27

The API_INIT used on the Development Board. Use the Lens Selection Guide in the ZMOTION Lens and Pyroelectric Sensor Product Specification (PS0286) ...

Page 28

Board Design Information Figure 9 displays the schematics for the ZMOTION Development Board. VCC_5v L1 L1 FERRITE BEAD FERRITE BEAD SH1 VBUS 7 2 SH2 SH3 SH4 ID 5 GND ...

Page 29

... San Jose, CA 95119 San Jose, CA 95119 San Jose, CA 95119 408-513-1500 408-513-1500 408-513-1500 Website: www.zilog.com Website: www.zilog.com Website: www.zilog.com Title Title Title ZMOTION Bundled Solutions 20-Pin Series Development Kit ZMOTION Bundled Solutions 20-Pin Series Development Kit ZMOTION Bundled Solutions 20-Pin Series Development Kit Page ...

Page 30

Figures 11 and 12 display top- and bottom-view mechanical drawings, respectively, of the ZMOTION Development Board. UM023301-0411 Figure 11. ZMOTION Development Board Mechanical Diagram, Top View ™ ZMOTION Intrusion Detection Development Kit User Manual 26 Board Design Information ...

Page 31

UM023301-0411 Figure 12. ZMOTION Development Board Mechanical Diagram, Bottom View ™ ZMOTION Intrusion Detection Development Kit User Manual 27 Board Design Information ...

Page 32

... To learn more about this product, find additional documentation discover other facets about Zilog product offerings, please visit the Zilog Knowledge Base at Zilog Forum at http://zilog.com/forum. This publication is subject to replacement by a later edition. To determine whether a later edition exists, please visit the Zilog website at  http://www.zilog.com. UM023301-0411 ™ ZMOTION Intrusion Detection Development Kit http://zilog ...

Related keywords