SP5004EGP Xeltek, SP5004EGP Datasheet

no-image

SP5004EGP

Manufacturer Part Number
SP5004EGP
Description
SUPERPRO 5004EGP PROGRAMMER
Manufacturer
Xeltek
Series
SuperPro®r
Type
Gang-Universal Programmerr
Datasheets

Specifications of SP5004EGP

Contents
Programmer, AC Adapter, Cable, CD
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With/related Products
EEPROM, EPROM, FLASH, MCU, NVRAM, PLD
Other names
415-1051
XELTEK 
Bldg 6‐31 Meizhiguo Garden, 
#2 Jiangjun Ave., 
Jiangning, Nanjing, China 
Tel:
Fax: (086) +25‐52765203 
www.xeltek.com.cn 
Superpro
Superpro
 
(086) +25‐52765233 
®
Ultra-Fast, Built-in 144 pins
5004GP User’s Guide 
Programmer of the Future
 
XELTEK
User’s Guide
 
®
5004GP

Related parts for SP5004EGP

SP5004EGP Summary of contents

Page 1

... XELTEK    Bldg 6‐31 Meizhiguo Garden,  #2 Jiangjun Ave.,  Jiangning, Nanjing, China    Tel: (086) +25‐52765233  Fax: (086) +25‐52765203  www.xeltek.com.cn  Superpro ® 5004GP User’s Guide  5004GP ®   1  ...

Page 2

... XELTEK.  The information in this document is subject to change without notice.  Software Copyright              2008‐2011 XELTEK  Userʹs Guide Copyright        2008‐2011 XELTEK Superpro ® ...

Page 3

... Chapter 1 General Description..........................................................................................9 Introduction to SUPERPRO 5004GP ............................................................................9 Package Contents ............................................................................................................9 Programming Hardware................................................................................................9 Software Features ..........................................................................................................10 System Requirements ...................................................................................................10 Chapter 2 System Installation..........................................................................................11 Software Setup...............................................................................................................11 CD‐ROM .....................................................................................................................11 Xeltek Website............................................................................................................12 Setup Process .................................................................................................................12 Hardware and Driver Installation ..............................................................................18 Chapter 3 SUPERPRO 5004GP Software Features .......................................................21 Main Screen....................................................................................................................21 Toolbar ............................................................................................................................22 Connect/DisConnect .................................................................................................22 Setting .........................................................................................................................22 Auto.............................................................................................................................23 Stop ...

Page 4

Chip Insertion – None‐DIP Encapsulation ....................................................28 Load File Screen.........................................................................................................28 Save File Screen .........................................................................................................32 Buffer Edit Screen......................................................................................................32 HEX/ASCII Data Buffer........................................................................................34 Fuse Buffer .............................................................................................................36 Encryption table ....................................................................................................37 Test Vector Table....................................................................................................37 Operation Option Screen..........................................................................................38 General....................................................................................................................39 Buffer.......................................................................................................................40 Auto Increment......................................................................................................41 Edit Auto Screen ........................................................................................................44 Device Configuration Word Screen ........................................................................47 U.E.S Screen................................................................................................................49 Setting Screen (Producer).............................................................................................50 Log File Screen...........................................................................................................51 Burning Status Window ...............................................................................................51 Output Window ............................................................................................................53 Statistical Window ........................................................................................................54 Chapter 4 Procedures .......................................................................................................56 Programming Procedure..............................................................................................56 Prepare the Hardware ..............................................................................................56 Prepare the Settings ..................................................................................................56 Start Producer Mode.................................................................................................58 Program the Chips ....................................................................................................58 Security and Password Input.......................................................................................59 ...

Page 5

Reading A Master Chip ................................................................................................61 Superpro ® 5004GP User’s Guide    5  ...

Page 6

Chapter 5 Detail Explanations on Common Problems................................................63 Dealing with Data Files ................................................................................................63 Solve Invalid File Type or File Data Overflow Error............................................63 Separate File Data for Programming......................................................................63 Program Two or More Files to One Chip...............................................................64 POF Format Files .......................................................................................................65 Adapter Selection ..........................................................................................................65 Selecting the Correct Adapter..................................................................................66 Other Messages..............................................................................................................67 Insertion Test Errors..........................................................................................68 Device ID Check Error......................................................................................69 Appendix............................................................................................................................70 Troubleshooting.........................................................................................................70 Contact Information..................................................................................................70 License Agreement............................................................................................................70 Warranty .............................................................................................................................73   Superpro ® 5004GP User’s Guide    6  ...

Page 7

... The programmer and software supports Windows XP and Windows Vista.  • The programmer is scheduled to support 43,000+ IC devices by the end of 2008.    Please check www.xeltek.com.cn for the list of the currently supported devices.  Superpro ® ...

Page 8

For authorized users, the SUPERPRO can provide for automatic generation of  electronic serial numbers.    IMPORTANT!  Make sure to complete the software installation before connecting  the programmer USB cable.  Manual Organization  This manual includes the following:  • An introduction to the SUPERPRO series, including the system requirements  and the software and hardware installation  • Detailed explanations on the commands and the programming procedures  • Information about error messages and common problems  • An Appendix that includes the customer support information    Note:  The software prevails in any discrepancy between it and the user manual,  due to any upgrades of the software.  The information in this document is subject to change without notice.    Superpro ® 5004GP User’s Guide    8  ...

Page 9

Chapter 1 General Description  This chapter provides information on the package contents, software features, and  system requirements for SUPERPRO.  Introduction to SUPERPRO 5004GP  The SUPERPRO is a cost‐effective, reliable, and high‐speed universal programmer  for mass‐production. They are designed to communicate with a USB 2.0 port of PC  by a standard USB cable. Online software provides friendly interface, powerful  functions and flexibility.  Package Contents  The standard package contains the following items:  • A programmer module  • A USB connection cable  • A power supply unit  • A software installation CD  • The User’s Guide  • A registration form  Programming Hardware    SP5004GP is a mass‐product programmer that can burn into four chips at the same  time. It contains four burning modules, as illustrated below. The module marked  “1” is the main module.  Superpro ® 5004GP User’s Guide      9  ...

Page 10

The programming hardware includes the following items: • 4 complete independent modules  • High programming speed  • 144 pin universal pin‐drivers design  Note:  Universal adapters, support devices with 144 pins or less, for support of  E/EPROM, FLASH, SCM, PLD, SRAM with normal or low voltage.  • Chip insertion test  • Asynchronous mode (Production mode)–operation starts as soon as the chip is  inserted in the socket  Software Features    The USB 2.0 Series supports:    • Windows XP and Windows Vista  • Over 25,000 (40,000+ by end of 2008) types of devices, including PROMs,  E/EPROMs, PLDs and MCU from more than 150 manufacturers  • Many types of formats such as Binary, Intel (linear & segmented) Hex,  Motorola S, Tektronix (linear & segmented), JEDEC, POF, etc.  • Device insertion test (144 pins or less)    • Integrated full screen buffer editing environment with commands such as fill,  copy, move, swap, etc.  • Project management  • Batch‐processing command  System Requirements  The minimum system configuration is as follows:  • ...

Page 11

... Software Setup  Select the software to setup your SUPERPRO programmer either from the  CD‐ROM or by downloading the program from the Xeltek website. Instructions  for both methods are described below.  CD‐ROM  ...

Page 12

... You can download the specific software for a certain model at Xeltek website:  http://www.xeltek.com.cn Select the icon to download the appropriate file for  your programmer. Once you have saved the file to your computer, run it to setup  ...

Page 13

Select your preferred language for the setup process from the drop down list.    2. Select OK.  The system displays the Install Wizard dialog box, illustrated below.  Superpro ® 5004GP User’s Guide        13  ...

Page 14

Next, the system displays the following dialog box.  3. Select Next to proceed to the next step.    The system displays the License Agreement, illustrated below.  4. Please read the license agreement carefully. Select I Agree to continue the  installation. To cancel the installation and exit the installation process, select  Cancel.  Superpro ® 5004GP User’s Guide        14  ...

Page 15

The system asks for the Destination Location, illustrated below.  5. Select Browse to choose the installation path. After selecting the desired  destination folder, select Next.  The system displays the Additional tasks dialog box, illustrated below.  6. Check the Create a start menu icon box to add an icon on the Start menu  during the installation. Check the Create a desktop icon box to add an icon to  the desktop during the installation. Select Next.    Superpro ® 5004GP User’s Guide        15  ...

Page 16

The system displays the following dialog box.  7. Review the settings you selected. Select Install to proceed to the next step.  Select Back to return to a previous step to change your selections.  The system displays the following dialog box.    The system copies the files, installs the drivers and registers the software.  Superpro ® 5004GP User’s Guide        批注 [mbw1]: Replace with  screen shot for 5004GP  16  ...

Page 17

If you are using Windows Vista, the system displays following dialog box.    8. Select Install this driver software anyway.    The system displays the following dialog box.  9. Select Finish to complete the setup process.  Superpro ® 5004GP User’s Guide        17  ...

Page 18

Hardware and Driver Installation    If you connect the hardware before installing the software, the system opens the  Found New Hardware Wizard, illustrated below.  1. Select Cancel to make sure the system does not install the wrong driver.  2. Return to the Software Setup process to setup the software before installing the  hardware. Refer to page 11 for instructions.  After you set up the software, you can install the hardware and driver. The  following procedure explains the installation process.  1. Make sure all other programs are closed during the installation process.  2. Connect the programmer module to the computer through the USB port.    3. Turn on the power switch of the programmer module.  Superpro ® 5004GP User’s Guide      18  ...

Page 19

When you connect the new hardware, the system initiates the New Hardware  Wizard, which locates the driver from the software you have just installed. The  system displays alerts one at a time, illustrated below. The alerts on your system  may be slightly different.                                          4. After you open the application software for the programmer, the system  automatically starts the initialization. This software manages four independent  modules, so it may take some time to communicate. The system displays a  Waiting window, illustrated below.      Stop any operations while this message displays and the system is  communicating with the programmer.  Superpro ® 5004GP User’s Guide        19  ...

Page 20

If the system does not automatically initialize, it may show a display similar to  that illustrated below.  5. Make sure the programmer is securely connected to the computer and that the  power switch is on.  Note:  The four modules are independent of each other. Under urgent  circumstances, if two or more modules are working, you can still use  SP5004GP.  Superpro ® 5004GP User’s Guide      20  ...

Page 21

Chapter 3 SUPERPRO 5004GP Software Features  This chapter gives detailed explanations of the software functions of the  programmer.  Important:  Set your monitor display resolution ratio to 1023*768 or above.  The main screen cannot be resized.    Main Screen  SP5004GP focuses on information needed for mass production. It includes a more  secure setting to ensure consistency in the burning process.  The main Superpro 5004GP screen is illustrated below. Each part of the user  interface is labeled with a number and described below.  1. The Toolbar includes icons to access common functions. Refer to the Toolbar  section on page 22 for more information.  Superpro ® 5004GP User’s Guide      21  ...

Page 22

The Burning Status window displays the burning process and instructs  operators to insert or take out chips. Refer to the Burning Status Window  section on page 51 for more information.  3. The Output window displays the running information of the program. Refer to  the Output Window section on page 53 for more information.    4. The Statistic window displays the number of times of successful programming  and the number of times of failed programming. Refer to the Statistical  Window section on page 54 for more information.  Toolbar  The toolbar is illustrated below. Each tool is explained in the following sections.  Connect/DisConnect  The programmer software uses Microsoft Winsock protocol to manage four  independent modules. The main screen is a management interface that controls  the hardware of the programmer by sending commands to the SP5000 software.  After the main interface, the process of communicating with the SP5000 software  starts automatically.  If the system does not find the programmer or something is wrong with a module,  select DisConnect to cancel the connection. Then check the connection between  the hardware and computer. Select Connect to reconnect.  Setting  The Superpro 5004GP has an Administrator mode and Producer mode to separate  management from production.    Select the Setting tool to choose whether to enter Administrator mode or Producer  mode. The system displays the Setting Mode screen, illustrated below.  Superpro ® 5004GP User’s Guide      22  ...

Page 23

Select either Administrator or Mass‐Producer to indicate the mode for which you  want to indicate the settings. Refer to the Setting Screen (Administrator) section on  page 23 or the Setting Screen (Producer) section on page 50 for more information.  Auto  After making the programming preparations, select Auto to start the programmer.  Stop  Select Stop to cancel the current operation.  Quit  You cannot quit while burning chips. After the operation is complete, or after  canceling the current operation, select Quit to exit the program. If you have set an  administrator’s password, you must enter the correct password to quit.  Setting Screen (Administrator)  When you select Administrator on the Setting Mode screen, the system displays  the Setting screen illustrated below. Each part of the screen is described below.  1. The system displays the name of the selected Device. Choose Select to open the  Superpro ® 5004GP User’s Guide      23  ...

Page 24

Select screen to select a device. Refer to the Select    section on page 25 for more  information.  2. The system displays the name of the loaded file in the File Name field. Select  Load File into Buffer to open the Load File screen to load a file. Refer to the  Load File Screen section on page 28 for more information.  3. After editing the buffer information, select Save Buffer into File to save data in  the current buffer to a disk file. The system displays the Save File screen. Refer  to the Save File Screen section on page 32 for more information.  4. Select Edit Buffer to open the Buffer Edit screen. Refer to the Buffer Edit Screen  section on page 32 for more information.  5. Select Checksum to open the Checksum for Compatibility screen. Refer to the  错误!未找到引用源。  on page  错误!未定义书签。  for more information.  6. Select Operation Option to open the Operation Option screen. Refer to the  Operation Option Screen section on page 38 for more information.  7. Select Edit Auto to open the Edit Auto screen. Refer to the Edit Auto Screen  section on page 44 for more information.  8. Select Dev. Config to open the ConfigWord screen. Refer to the Device  Configuration Word Screen section on page 47 for more information.  9. Select U.E.S to open the User Electronic Signature Bytes screen. Refer to the  U.E.S Screen section on page 49 for more information.  10. Check the Production Mode box to program devices in large quantities. The  programmer uses the Insertion Test to automatically detect insertion and  removal of devices and carry out the entire programming process.    11. A project file allows you to save a working environment, including the device  ...

Page 25

Select OK when you have finished indicating the Administrator settings.  Select Device  When you choose Select on the Setting screen, the system displays the Device  Selection dialog box, illustrated below. Each part of the screen is described below.  1. Select one of the following Device Types:  • E(E)PROM (including EPROM, EEPROM, FLASH)  • B/PROM  • DRAM/SRAM  • PLD  • MCU  Select ALL if you are not sure what type to choose.  2. In the Manufacturer box, highlight the desired manufacturer. The lower right  corner displays the manufacturer logo to help ensure you select the correct  manufacturer.  Superpro ® 5004GP User’s Guide    25  ...

Page 26

Highlight the correct device in the Device Name box.  NOTE: The chip’s printed name may include the parameters (i.e., speed,  temperature, encapsulation, etc.). If the name is different than what  appears in the Device Name column, you may ignore the difference or ask  for help.    You may use the Search box to help select the device from the large quantity of  devices listed. Enter the first few characters of the device name to limit the  number of choices listed in the Manufacturer and Device Name columns. For  example, if you enter 89 in the Search box, the list only shows Manufacturers  and Devices that contain ‘89’. The sequence of the characters is important. For  example, if you enter ‘89’, the list includes ‘819’, and ‘DA8S9’ but not ‘98’.  4. Select Dev.Info to open the Device Information screen. Refer to the next section  for more information.  5. Select OK or Cancel.  Superpro ® 5004GP User’s Guide    26  ...

Page 27

Device Information Screen  When you choose Dev Information on the Select screen, the system displays the  Device Information, illustrated below. Each part of the screen is described below.  The device information includes the following information:  • Key information about the devices  • The manufacturers’ requirements  • The conventions on the special devices  Note:  Some devices may have special requirements, including the  arrangement of the data buffer content, and the explanations on the  special operations of the device. Read the information carefully.    To ensure correct programming, arrange the data and prepare the  corresponding settings according to the requirements. You can also  find this information in the data manual of the device.    Superpro ® 5004GP User’s Guide      27  ...

Page 28

The adapter information, which may include the order number (such as  CX5001), the size of the chip, and the chip insertion direction.  Note:  To program chips with other than the standard encapsulation, you  must purchase the appropriate adapters.  Chip Insertion – DIP Encapsulation  Insert the chip with the notch upwards, aligning the bottom line with the bottom  line of the socket. The diagram below illustrates the process of inserting a 28‐pin  chip.    Chip Insertion – None‐DIP Encapsulation  Socket adapters are available for other encapsulations, including PLCC, QFP, and  SOIC. Refer to the Adapter Information on the Device Information screen. The  insertion follows the position of pin 1.    To identify pin 1 of the chip, look for a solid square or dot on the chip that gives  the information about the chip. It also indicates the first pin of the chip.    Note:  Generally, the pins of the chip are downward when they are inserted.  However, as for the chip PLCC20, its pins should be upward. This  insertion is called the “Dead Bug” method.    Load File Screen  There may be one or more data buffers in the device. If several data buffers are  displayed after you have selected the device, refer to the name and the data  Superpro ® 5004GP User’s Guide      28  ...

Page 29

The two data types of the device are Data (HEX/ASCII) and Fuse.    • For most EPROM and SCM, the data type is Data (HEX/ASCII).    • The data type for PLD device is Fuse.    After you select the device, the software automatically identifies the data buffer  type. You can review the buffer data types if you open the Edit Buffer screen.  Refer to the Buffer Edit Screen on page 32 for more information.  When some file data are loaded into the data buffer, the following rules apply:    • With a HEX/ASCII data buffer (EPROM, MCU etc.), the system assumes that 8  bits of the data are valid.  • With a JEDEC buffer (PLD/PAL), the system considers the lowest bit (1 bit) of  the file data valid.  When you select Load File into Buffer from the Setting screen, the system  displays the Load File screen, illustrated below. The red labels refer to the  numbered explanations below. 1. Select the data Buffer name from the drop down list, as illustrated below.  Superpro ® 5004GP User’s Guide        29  ...

Page 30

The default option is considered the programming zone of the device as  described in the data manual.  • To choose between several buffers, determine the corresponding  programming zones according to the names and the data manual.  The system loads the file data into the data buffers according to the data buffer  names.    2. Enter the name of the data file to load in the File Name field.      Alternatively, you can select Browse and choose the file using the Select File  box, which is illustrated below.      First select the file type from the Files of type drop down list.    • Data (HEX/ASCII data) file types can be further divided into many different  types according to their storage forms. You must select the appropriate file  type to ensure the data loads correctly.  • The file type for Fuse data files is JEDEC and the file extension is “jed.”  After selecting the file, you do not need to select the data file type.  Altera Corporation uses POF format files. To program an Altera Corporation chip,  refer to POF Format Files on page 65 for more information.  3. Select the File Type from the drop down list.      4. Select one of the following File Modes from the drop down list:  • Normal to load the whole file  Superpro ® 5004GP User’s Guide    ...

Page 31

Even to load the first byte and discard the second byte out of every two  bytes  • Odd to discard the first byte and load the second byte out of every two  bytes  • 1st byte of 4 to load first byte and discard the other three bytes out of every  four bytes  • 2nd byte of 4 to load the second byte and discard the other three bytes out  of every four bytes  • 3rd byte of 4 to load the third byte and discard the other three bytes out of  every four bytes  • 4th byte of 4 to load the fourth byte and discard the other three bytes out of  every four bytes  • 1st 2_byte of 4 to load the first two bytes and discard the other two bytes  out of every four bytes  • 2nd 2_byte of 4 to load the last two bytes and discard the other two bytes  out of every four bytes  Refer to the Separate File Data for Programming section on page 63 for more  information.  5. The Buffer Address field displays the start address of the data loaded into the  buffer.  6. The system displays the minimum offset address in the File Address field.      Some Hex or S record files contain non‐zero file start addresses. If the file type  has a non‐zero start address, enter the data offset address in the File Address  field. Make sure to enter the correct address, because an incorrect file offset  address causes part of the buffer to be filled with FF (or incorrect data). This  causes a system overflow or failure. Refer to Solve Invalid File Type or File  Data Overflow on page 63 for more information on this problem.  7. ...

Page 32

Save File Screen  When you select Save Buffer into File from the Setting screen, the system displays  the Save File screen, illustrated below. The red labels refer to the numbered  explanations below.  1. Select the Data Buffer Name from the Buffer drop down list.  2. Enter File Name for Data or select Browse to select a file name.  3. Select the type of file from the File Type drop down list.  4. Enter the start address of the data buffer in the Buffer Address field. The saved  data starts at the start address.  5. Enter the save data size in number of bytes in the Save Data Size field.  Buffer Edit Screen  When you select Edit Buffer on the Settings screen, the system displays either the  Fuse Buffer Edit window or the Data Buffer (HEX/ASCII) Edit window,  depending on the file type.  Use the following keys to edit the buffer data:  • Press the Page Up key to Page up in the data window.  • Press the Page Down key to Page down in the data window.  • Press the Home key to move the cursor to the beginning of the line.  • Press the End key to move cursor to the end of the line.  Superpro ® 5004GP User’s Guide    32  ...

Page 33

The following sample illustrates an example with two data buffers. The red labels  refer to the numbered explanations below. Note:  You can open several data buffers at the same time.  1. The tabs in the lower left corner allow you to switch from one data buffer to  another. The current data buffer name is highlighted.  2. Select Duplicate to save the data in the buffers in text form. The following  examples show the text form of the saved buffer data.  • HEX/ASCII data buffer:    00000000 00- MZ.._..._....... 00000010 00-40 00 ...

Page 34

HEX/ASCII Data Buffer  A sample Data Buffer (HEX/ASCII) Edit window is illustrated below.  The HEX/ASCII data buffer is 8‐bit wide. Press the TAB key to switch between  HEX and ASCII data for editing.    Note:    Remember that the value of start address must be less than that of the end  address. 1. Select Buffer clear at IC change to clear the buffer after selecting the device.  2. Select Buffer clear on data load to clear the buffer before loading the file data.  3. Select Buffer save when exit to save the buffer data when exiting. This option  also loads the saved data automatically the next time you enter the system.  4. Select Locate to open the Locate Buffer dialog box. Enter the address of the  data you wish to display and select OK to quickly move the cursor to the  desired location.  5. Select Copy to open the Copy Buffer dialog box.    • Enter the start address in the Start Address field.  • Enter the end address in the End Address field.  • Select OK to copy the data between the start address and the end address,  beginning with a new address. Otherwise, select Cancel.  Superpro ® 5004GP User’s Guide    34  ...

Page 35

Select Fill to open the Fill Data Into Buffer dialog box.    • Enter the desired data in the Fill Data field. The data consists of HEX  numbers, such as AA, 55, E4 for the Data Buffer (HEX/ASCII data) Edit  window.  • Enter the start address in the Start Address field.  • Enter the end address in the End Address field.  • Select OK to fill the data. Otherwise, select Cancel.  7. Select Search to search for a specified string.  8. Select Search Next to begin the next search for the specified string.  9. Select Radix to toggle between the HEX and DEC memory address display.  10. Select Swap to open the Word Swap dialog box, illustrated below.    Select the Word Width option to swap high byte and low byte according to the  specified width in the address range and select OK. Otherwise, select Cancel.        For example, if the data buffer address 0‐10(HEX) is:  ...

Page 36

Fuse Buffer  A sample Fuse Buffer Edit window is illustrated below.    The data for editing is either 0 or 1. Refer to the data manual of the device and the  JEDEC to determine which of the following explanations for the data apply.  • 1 represents an intact fuse and 0 represents a blown fuse  • 1 represents a blown fuse and 0 represents an intact fuse  Refer to the HEX/ASCII Data Buffer section on page 34 for more information about  the options on this screen.  Superpro ® 5004GP User’s Guide      36  ...

Page 37

Encryption table    A data buffer corresponding to the encrypted data is called an encryption table.  Whether an encryption table exists depends on the data manual.    A sample Encryption table is illustrated below.  The Encryption function writes the encryption table data into a chip. In most cases,  you cannot check the chip after the data is written into the encryption table. The  encryption table data also cannot be read.  Test Vector Table  The test vector table is a special data area. The data buffer corresponding to the  data is called the test vector table.    If a test vector table is included in the JEDEC file, the software loads the test vector  table into the buffer when you load the file. Each line displays one vector. Each bit  represents one pin’s test characteristic. The bits from left to right correspond to the  pins from the first to the last respectively.    Superpro ® 5004GP User’s Guide      37  ...

Page 38

A sample vector table is illustrated below, with definitions following.  • Z: High impedance state  • X: No care state  • N: VCC or GND (non‐test input pins)    • H: Output Logic High (VOH)  • L: Output Logic Low (VOL)  • C: Clock pin  • 1: Input Logic High (VIH)  • 0: Input Logic Low (VIL)    Operation Option Screen  Select Operation Option from the Setting screen to open the Operation Option  screen.    Note:  Using the Operation Option to change the settings may produce minor  changes from the following descriptions.  The Operation Option screen includes four views:  • General  • Buffer  Superpro ® 5004GP User’s Guide      38  ...

Page 39

Auto.Inc  • Count  Each view is explained in the following sections.  General    The General view of the Operation Option screen is illustrated below.  1. Select Insertion Test to have the programmer check the pin contact status  before programming. The test includes a check for poor contact, wrong  direction, chip insertion, and chip insertion orientation errors. Refer to  Insertion Test Errors on page 68 for more information.  2. Select ID Check to have the programmer read the Electronic Identifier Code  from the chip to identify the manufacturer, the device type and the  programming algorithm code. If you have already selected the device, the  default for this option is checked. Refer to Device ID Check Error on page 69  for more information.  3. Select Beeper On to turn the beeper on or off. The beeper makes a sound to  indicate the results of operations such as Insertion Test error, ID unmatched,  programming successfully completed or failed.  Note: Not all programmers include a beeper.    4. Indicate the mode for verifying the data by selecting one of the Verify Mode  Superpro ® 5004GP User’s Guide      39  ...

Page 40

MinVcc and MaxVcc values for verifying the data.    VCC(+/‐ 5%) or VCC(+/‐ 10%) is adopted for the verification. If VCC = 5.00V,  select one of the following options:  • VCC = 5.00V and verify the data once  • VCC = 4.75V and VCC = 5.25V, and verify the data twice (+/‐ 5%)  • VCC = 4.50V and VCC=5.50V, and verify the data twice (+/‐ 10%)  Buffer    The Buffer view of the Operation Option screen is illustrated below.  The default programming method is to program the device from the start address  to the end address. However, you may choose to program only a part of the chip,  such as with most E/EPROM (FLASH) devices.    Note:    Most single‐chip microcomputers do not allow a change to the start  address of the device.  1. For each file, enter the Start Address.  2. For each file, enter the End Address.  Superpro ® 5004GP User’s Guide      40  ...

Page 41

EXAMPLE:  The device MACRONIX MX29F200B TSOP48 is a 16‐bit flash  device. Its programmable zone starts at the address 0 and ends at the  address 1FFFF (hexadecimal system).      The buffer size in bytes is (1FFFF+1) * 2 = 40000 (hexadecimal  system).      Because it is a 16‐bit (2 bytes) device, the buffer size is twice as large  as the device size.      To program only the second part of the device, enter 10000 as the  start address and leave the end address unchanged. This correlates  the programming data to the buffer data between the address  10000*2 = 200000 and 40000.  Auto Increment    The Auto.Inc view of the Operation Option screen is illustrated below.  Auto Increment provides two methods of generating the serial numbers: Auto  Increment and User Defined.    Note:  The serial number is the content required by some applications that must  be written in a certain area for every chip. This information includes the  product sequence number and the MAC address.  Superpro ® 5004GP User’s Guide    41  ...

Page 42

To have the software generate the serial number, select Enable AutoIncrement.  1. Enter the automatic start buffer address in the Start Addr field.    2. Enter the automatic end buffer address in the End Addr field.  3. Enter 1 in the Inc. Step field.  4. The AutoInc Format defines the start value and the overflow value. The  overflow value is the number at which the increment ceases and carries to the  next address, which becomes the new start value.  • Select Binary to set the start value as 0 and the overflow value as 256.  • Select ASCII Decimal to set the start value as 30 (hexadecimal  representation of 0) and the overflow value as 39+1 (the hexadecimal  representation of 9).  • Select ASCII Hex to set the start value as 30 (hexadecimal representation of  0) and the overflow value as 46+1 (the hexadecimal representation of a  number greater than F, where 9+1=A).  Superpro ® 5004GP User’s Guide    42  ...

Page 43

Example:  There are 64 chips with IDs from 0001 to 0064, which are in the end  address of 89C51 EPROM. The selected mode is 4 bytes, using the  decimal system.    1.  Enter FFF in the Start Address field.      2.  Enter FFC in the End Address field.    3.  Enter 1 in the Inc.Step field.    4.  Select ASCII Decimal as the AutoInc. Format.    In the Buffer Edit window, make the following change:    FFC: 30 FFD:   The Operation Information window displays the following  information during programming:    Current AutoIncrement Data=0001    In subsequent programming operations, the information in the last 4  bytes of the buffer data is:    FFC: 30 FFD: After successful programming, the AutoIncrement value increases  by 1. The Operation Information window displays the following  information:    Current AutoIncrement Data = 0002  ...

Page 44

Edit Auto Screen  The Auto function organizes the different functions of the device into a sequential  group and carries out the functions in order, similar to a batch command.    When you select Edit Auto on the Settings screen, the system displays the Edit  Auto screen, illustrated below. The illustration is a sample for the device ATMEL  AT89C51.  The Device Functions column displays all operations for the device.    The Auto column lists the operations in order of execution. For the sample in the  illustration, the operation execution order is Erase, Blank_check, Program, Verify.  1. Select Add to add the highlighted function in the Device Function column to  the end of the Auto column. You can also double‐click the highlighted function  in the Device Function column to add it to the Auto column.  2. Select Delete to delete the highlighted function in the Auto column. You can  also double‐click the highlighted function in the Auto column to delete it.  3. Select Delete All to remove all the functions from the Auto column.  Superpro ® 5004GP User’s Guide      44  ...

Page 45

... Information screen, or contact XELTEK technical support.  • Auto is the automatic programming mode, which executes a series of  ...

Page 46

Notes:  If there is any discrepancy, verification ceases and the system displays  a failure message. For most memory chips and SCM chips, the failure  message includes address and data. For PLD devices, the message  displayed depends on the programming reference. Only the chips that  pass verification can be recognized as the chips being programmed  correctly.      Some chips do not provide the cell to cell check function. Instead, these  chips provide only the accumulation check function similar to the  VerifyCRC.      A few chips do not provide the accumulation check function. The  system performs the check automatically in the programming process.      • Blank_check checks if the device is in blank state, which is dependent on the  data manual. If filling the blank data buffer is selected when the devices are  selected, the programmer will fill all the HEX/ASCII buffer data with FF or 00  (Hex), and the fuse buffer with 1 or 0 after the device is selected. An encrypted  chip may be displayed as a blank chip.    Notes:  EEPROM devices do not need Blank_check because the chip can be  overwritten.    Refer to Making a Chip Blank on page 60 for more information.  • Erase erases the chip and makes it blank. This operation can only be executed  on the chip that can be erased electrically. EEPROM does not need to execute  this operation. If you need a chip with a blank state, you can directly write the  blank data to the chip. Some chips that can be erased electrically are able to  become an OTP by configuring the ConfigWord. Please refer to the device data  manual.  • Protect encrypts data to make it unreadable. Protect affects the operation  function whether it is readable or not.  ...

Page 47

The Protect function protects the data in FLASH chips. You cannot rewrite  a protected chip until you have removed the protection. Use the Erase  operation to remove the protection. You must use this operation with Dev.  Config and identify the sector. Refer to Identifying the Sector on page 60 for  more information.  • Security encrypts data to make it unreadable.    • Erase_All is the same as Erase.    • Protect_All is the same as Protect.    • Lock_Bit is a protection method. Please refer to the Device Data Manual for the  detail information about the operations.    Example:   Atmel At89C51 has three operation items: Lock_Bit1, Lock_Bit12,  Lock_Bit123. The data manual defines the meaning of each.    Device Configuration Word Screen  Important:   The device configuration word varies from device to device. Refer to  the device data manual for more information about the configuration  words. Set the configuration words according to the requirements of  your target system. Otherwise, you cannot use the device normally  even if it is normal when preparing and verifying the program.    Some single‐chip microcomputers allow special working modes, such as the  storage area mapping, the watchdog time, the clock, or the encryption. Set these  special modes through the Device Configuration Word option.    The user files contain the configuration words of some devices. When you load  these files, the system automatically loads the configuration words into the  configuration word buffer. However, you must select the configuration words for  ...

Page 48

Select Dev.Config on the Settings screen to open the ConfigWord dialog box. The  following sample illustration shows the configuration word for DALLAS  DS89C420. It contains the watchdog and three protection modes.    Some single‐chip microcomputers include many items for the configuration word.  The items may appear on separate tabs or pages. Make sure to set all the items on  all pages before programming a chip.    The input of the configuration word can be divided into several ways:    • The 8‐bit (byte) edit box input  • The 16‐bit (word) edit box input  • The single choice input (select and deselect, choose one out of two)  • The multiple choice input (choose one out of many)  Superpro ® 5004GP User’s Guide      48  ...

Page 49

The configuration words for chip programming are classified into two categories:    • If the configuration word contains some protected items, then you cannot  verify the items after preparing the program. When preparing the program, the  programmer automatically shields the protected items and writes the other  items. Select Security or Protection to write the protected items.    Note:  If you select None as the Protection option, the system does NOT carry  out an operation when performing Security or Protection.  • In some devices, the configuration words cannot be separated, so the system  does not write the configuration word when preparing the program. To write  the configuration word in these cases, select the corresponding item, such as  Write_Option.    Some FLASH devices also use the configuration word for the Protect operation  and to execute and display the segment protection.    U.E.S Screen  When you select U.E.S from the Settings screen, the system displays the User  Electronic Signature Bytes screen, illustrated below.  This screen allows you to view and edit the user’s electronic signature in both  HEX and ASCII formats. When reading devices or loading files, the content may  be changed.    Superpro ® 5004GP User’s Guide      49  ...

Page 50

... Note:  To avoid errors from complicated burning processes, choose the same  project for all four modules. Check the Same project for all sites  checkbox. Contact Xeltek if you have a special request.  Select Browse to select the project file.  ...

Page 51

Select OK to indicate the settings are complete, or select Cancel close the  Setting screen without making changes.    Log File Screen  You can create a log file to have the system save Output window content into a log  file when you exit the program. Select Log File from the Setting screen to open the  Log File dialog box, illustrated below. The red labels refer to the numbered  explanations below. 1. Select No to delete the log file. The system will not create a log file on exit.  2. Select New to overwrite the existing log file every time the program starts.  3. Select Append to add the log file information at the end of the existing log file  each time the program starts.    4. Enter, edit or Browse for the full path name of the log file in the Log file’s  name: field.    Burning Status Window  After finishing the programmer’s settings, you can burn devices. Watch the  burning process and instructions for inserting and removing chips in the Burning  Status window, illustrated below. Each part of the user interface is labeled with a  number and described below.  Superpro ® 5004GP User’s Guide      51  ...

Page 52

The production mode status is set by project.  2. The message displays one of the following options:  • Ready: The module is connected or the burning succeeded.  • Failure: The operation failed. View the detailed information in the output  window.  • No Programmer: The module is not connected.  3. The Indicator Light displays one of the following options:  • Green indicates Succeed or Ready  • Yellow indicates At work. The message section includes a display of process  completion, as illustrated below.    • Red indicates Failed.  Note:  Refer to the corresponding message for details.  4. The system displays the Module ID.  5. The system displays the Device Name and checksum.  6. The system displays the current Serial Number (if set).  Important:  Make sure to check the operation result in the following instances:    1.  In non‐production mode, the Stop icon on the Toolbar is gray,  as illustrated below.    Superpro ® 5004GP User’s Guide    ...

Page 53

In production mode, the message indicates to remove the  device, as illustrated below.      Output Window  The Output Window, illustrated below, displays the running information of the  program. This information is saved into the log file as text format when you exit  the program.  This window includes five tabs, as explained below.  • Main:  The main window displays the history records about the main  interface.  • #1‐#4:  The other four tabs correlate to the modules. Each windows displays  specific information about the related module, including device selection, chip  burning, and reasons for failure.  Superpro ® 5004GP User’s Guide    53  ...

Page 54

Statistical Window  The Statistical Window, illustrated below, displays the number of times of  successful and failed programming.  The system displays the following information according to the default counting  rules:    • Success: number of times of successful programming for each module and the  total  • Failure: number of times of failed programming for each module and the total  • Sum: total number of times of programming for each module and the total  • Yield: the percentage of success for each module and the total  After successful Program execution, the Success count increases by 1. Otherwise  the failure count increases by 1.    Select Reset to set the successful times and the failed times back to 0.    Select Reset Count Down to open the Count Down dialog box, illustrated below.  The red labels refer to the explanations that follow.  Superpro ® 5004GP User’s Guide        54  ...

Page 55

Enter the number of chips you are programming (greater than 0) to have the  system count down. The Count Down number decreases by 1 every time a  chip is programmed successfully, until it reaches 0.  2. Check the Count Down: enabled box to enable the count down function.    3. Check the Stop when reading the total box to ensure that no more programs  are written until you reset the option.    Superpro ® 5004GP User’s Guide    55  ...

Page 56

Chapter 4 Procedures  This chapter provides information on steps for common procedures.  Programming Procedure  This section presents the operation process for the chip programming, from the  beginning to the end, including the user interface and the device programming  steps.  Before you start to program any devices, make sure that you have correctly  installed the programmer and that the computer is successfully communicating  with the programmer.  It is best to detach management from production so that during production, you  only need to watch the burning process.    Use the administrator mode to set the working environment for the burning  devices. The four modules work the same, including devices, data, and operation  options.  Prepare the Hardware  You can only enter administrator mode if the computer and programmer are  communicating successfully.  Make sure that you have the appropriate adapter for your SMD devices, if  applicable.  Insert the chip correctly. Follow the guidelines of the standard chip insertion  markings near the pin‐driver socket. However, if you select SMD or a device that  requires non‐standard insertion, the system prompts you with the appropriate  chip insertion.    Prepare the Settings  1. Select the Setting icon on the Toolbar. The system displays the Setting Mode  screen.  2. Select Administrator and OK.  The system displays the Setting screen.    3. Select the device. Refer to the Select    section on page 25 for more information.  4. Load the data into the buffer. Refer to the Load File Screen section on page 28  for more information.  ...

Page 57

Instead of loading a file, you can read the data from a master chip. Refer to the  Reading A Master Chip section on page 61 for more information.    Note:  The read function is not available for some devices, including those  that have been encrypted.  5. Make sure the loaded data is correct by viewing on the Buffer Edit window.  Refer to the Buffer Edit Screen section on page 32 for detailed information.  6. Select Operation Option on the Setting screen to open the Operation Option  screen. Set each of the following options:  • Insertion Test option to indicate whether to check the pin contact before  programming  • Device ID Check option to indicate whether to check the ID of the device  before programming  • Beeper option to indicate whether the beeper beeps when the operation  succeeds or fails  • Verification Mode option to select a specific VCC voltage to ensure that the  chip is programmed correctly  Refer to the Operation Option Screen section on page 38 for more information.  7. Select Edit Auto on the Settings screen to set the order of the batch processing  functions. The functions usually selected are Erase, Blank_check, Program,  Verify, and Security or Protect. Refer to Edit Auto on page 44 for more  information.  8. For devices that include the configuration word, you must set the  configuration word before programming to ensure that the chip can be used on  the target system.      The configuration words for some devices are contained in the data file.  Therefore, the system automatically loads the configuration word into the  configuration word buffer when loading the data file.  ...

Page 58

Select Save Project on the Setting screen to save all of the current settings into a  specified project.    Start Producer Mode  1. Select the Setting icon on the Toolbar. The system displays the Setting Mode  screen.  2. Select Producer and OK.  The system displays the Setting screen.    3. Select Browse to open the project file you saved in the Administrator mode.  Refer to the Setting Screen (Producer) section on page 50 for more information.    Program the Chips  The operation steps for programming a chip, as set in Edit Auto, are follows:    • Blank Check  Notes:  Y ou can skip this step if the chip is brand new.    The Blank Check will fail on chips containing some information that can  be erased. In this case, perform the Erase operation first. You do not  need to erase EPROM chips for which the data can be overwritten.  • Program  • Verify  Note:  This step is necessary. The chip must pass Verification before the  programming can be implemented. Some chips provide only the  accumulation check function, such as VerifyCRC instead of a  unit‐to‐unit check function. Very few chips do not provide the  accumulation check function.  ...

Page 59

Toolbar.  2. Insert the chip properly into the socket. If the prompt information indicates a  need for an adaptor, you may purchase the adapter.    The programmer waits for the chip insertion. The system displays the  following prompt: Please, insert a device into the socket.    3. Once you have properly inserted the chip, the auto batch‐processing command  starts automatically.  4. The programmer waits for the chip removal. When chip programming is  complete, the system displays the following prompt: Please, remove the  device from the socket.    5. Review the Output window to check the programming result.                Security and Password Input    To prevent the user’s data from being used by another, the program asks the user  to input the password in the operation process.  The Set Password screen is illustrated below. 1. Enter the new password in the Enter the password field. Leave the field blank  to indicate no password is required.  Superpro ® 5004GP User’s Guide    59  ...

Page 60

Re‐enter the password. Both fields must match for a valid password.  Note:  Spaces are characters that can be used in the password.  The system asks for a password whenever performing a function that requires a  password. The Enter Password screen is illustrated below.  Making a Chip Blank  For the chip that can be erased electrically, execute the Erase operation.    For the chip that can be erased with ultraviolet ray, use the ultraviolet ray eraser  for 3‐30 minutes.  Note:  OTP cannot be blanked once written.      Identifying the Sector  You must identify the Sector to protect some chips.    There are two ways to select the Sector:    1. Enter the address of several sectors (maximum of 8)to decide the sectors to  protect. After the Protect operation is performed, the identified sectors are  protected.    Superpro ® 5004GP User’s Guide      60  ...

Page 61

If the chip has been divided into several sector groups in advance, you can  only choose these groups to be protected, as shown in the following  illustration.               Reading A Master Chip  The system can read a master chip to the buffer, which allows you to copy a  master chip to the chips in the other modules,    Superpro ® 5004GP User’s Guide    61  ...

Page 62

To read a master chip, complete the following steps:  1. Insert the master chip in the first module.  2. Edit Auto to include only the Read function item.  3. Select Auto from the Toolbar.    4. Take out the master chip.  To make sure the read succeeded, complete the following steps:  5. In Administrator mode, select the device. The type of the device should be the  same as the master chip.  6. In administrator mode, edit Auto again with the appropriate programming  functions to program a new chip.    7. Save the project.  8. With a new chip, execute the programming process with the saved project.    If the new chip works in the target board like the master chip, the copy succeeded.    Superpro ® 5004GP User’s Guide    62  ...

Page 63

Chapter 5 Detail Explanations on Common Problems  You can monitor the programmer operations through the Operation Information  Window and message window. This chapter helps define common problems  related to programmer actions and errors.  Dealing with Data Files    This section explains common problems involving the File Type dialog box.    Solve Invalid File Type or File Data Overflow Error  The data for programming is usually stored in the data file. Commonly used  formats are Intel Hex, Motorola and Tektronix. The files of these formats keep data  in text mode, which include data and address information. Because the offset  address is not always zero, you may incur errors when loading the file directly.  For example, the location of data in buffer (as viewed in the Edit Buffer window)  may be incorrect or you may receive an error message when loading the file, such  as “Invalid file type, or all file data overflow”.  Select one of the following options to solve this problem.  • Confirm the file type and ensure the buffer can load all the files.    • Find the offset address of the file. When loading the file, select the Show  Offset Address (Minimize) After Loading option to display the start address  of the file after the file is loaded.    Example:  File Offset Address (min): 0x0000E0000 (Hex)    This means the offset address of the file is not 0. You must move the  data at the address to the address 0 of the buffer. To do that, load the  file again, and enter E000 as the File Address.  Refer to the Load File section on page 28 for more information on loading files.  Separate File Data for Programming    By using the File Mode selection in the File Type dialog box, you can select the  data of a file and write it to several chips of the same type. This allows you to load  the file several times according to your needs.    There are three methods for separating the file data.  1. ...

Page 64

Program the two parts into two chips respectively.      When loading the file, select Even as the File Mode to write the data in the  addresses 0,2,4,6, etc. to one chip. Select Odd as the File mode to write the data  at the address 1,3,5,7, etc. to the other chip.    2. Based on the byte (8‐bit), divide the file into four parts by address of the first  byte, the second byte, the third byte and the fourth byte out of every four bytes.  Program the four parts to four chips respectively.      When loading the file, select the 1 in the addresses 0, 4, 8, 12 (or C if HEX), etc. to one chip. Then select 2 4, 3 rd  byte of 4, and finally 4 three chips.  3. Based on the word (16‐bit), divide the file into two parts by address of the first  two bytes and the last two bytes out of every four bytes. Program the two parts  to two chips respectively.      When loading the file, select the 1 data in the addresses 0, 1, 5, 6, etc. to one chip. Then select 2 write the remaining data to the other chip.  Program Two or More Files to One Chip  You can load several files into the buffer and write them to the chip. The following  explanation gives an example of programming three files (Sample1, Sample2, and  Sample3) to one chip. The example assumes the following:  • Write the data from the address 200 (Hex) of the file Sample1 to the address 0  of the chip.  • Write the data from the address 0 (Hex) of the file Sample2 to the address 3000  (Hex) of the chip.  • Write the data from the address 4000 (Hex) of the file Sample3 to the address  ...

Page 65

Select Load from the File menu to load the Sample2 file.    • In the Buffer Address field, enter 3000.    • In the File Address field, enter 0.    4. Select Load from the File menu to load the Sample3 file.    • In the Buffer Address field, enter 4000.    • In the File Address field, enter 4000.    5. Continue with programming.    If there are no changes in the file requirements or content of the three files  (Sample1, Sample2, and Sample3), you can save the data in buffer to a new file,  such as Sample4, for easy loading and programming next time.    POF Format Files  When programming ALTERA PLD devices the system saves the data in POF  format files. When loading a POF Format file, the system displays a File Type  dialog box. Select one of the following:    1. POF file: The system transforms the data into the Fuse data and checks the data  when you load it to the buffer. You may receive one of the following errors:  • Unmatched file to this chip: This POF file does not match this chip. The  POF file is related to the device when it is compiled. The error indicates that  this POF file is not for this device. Replace the chip with a matched one.  • The POF file has errors.  • ...

Page 66

Specific adapters are applicable for certain devices only. For example, if the  number of the pins for economical programmer hardware is not enough,  specific adapters may solve the “insufficient number of the pins” problem. This  way, the programmer can also support devices with more than 48 pins  To use devices with pins between 48 and 144, you can choose either the universal  adapter or the specific adapter.  To use devices with pins more than 144, you must use the specific adapter.  Selecting the Correct Adapter  The Device Information screen displays adapter information. The following  illustration shows PLCC44 as an example.    In this example, the adapter order number is CX2044 or CX2144. Superpro ® 5004GP User’s Guide    66  ...

Page 67

... There are different order numbers for adapters because the sockets are from  different manufacturers. There may also be a minor difference in size.  Note:  To ensure success, do not use self‐made adapters. For best results, obtain  the adapter made by Xeltek.        ...

Page 68

Programmer not found: The programmer is not connected to the PC or it is  connected improperly. Check the connection. Refer to Chapter 2 System  Installation on page 11 for more information.  • Programmer not ready: Turn off the programmer power switch and turn it on  again after a few seconds.    • Programmer is running: The programmer hardware is operating. Wait until  the operation is finished.    • File open error: The open file operation failed.    • Out of Memory: The memory overflows.    • Production mode isnʹt available for this chip: Since the production mode is  dependent on the pin check, the chips without pin check function are not  applicable for production mode.  • Cancel production mode: Cancel the production mode.    • Too long file name: The file name is too long.    • User cancel: The system displays this message after you select Cancel on the  Status bar.    • Canʹt cancel!: The Cancel operation has failed.    • Not a project file: The file selected is not a project file. After the software is  updated, the software may not be able to identify a previously created file. You  ...

Page 69

Device inserted upwards 3 slots!: The chip has been inserted improperly.  Refer to Device Information on page 27 for more information.  • An unmatched device (40 pins) inserted!: If the system detects pin contact  errors for a chip with more than 48 pins, it displays the serial number of the  DIP socket of the programmer. Check the adapter.  For any insertion test error messages, choose one of the following options.  • Select Abort to stop the programming.  • Select Retry to run the Insertion Test again after correcting the problem.  • Select Ignore to continue the program.                    Device ID Check Error  If you selected the ID Check option on the Operation Option (General) screen, and  the system checks the device ID. The system displays the following error message  if it detects an error. • Select Yes to ignore the error and continue programming.  • Select No to abort the programming. When the ID is unmatched, the system  searches for matched devices and display them in the Operation Information  window.    Superpro ® 5004GP User’s Guide      69  ...

Page 70

... Email: sales02@xeltek.com.cn  Superpro ® ...

Page 71

... Technical Support            +86‐25‐52765233                                              Email: Service@xeltek.com.cn      Fax   ...

Page 72

... License Agreement  The copyright of the program and the Userʹs Guide remain the property of  XELTEK.  You may:    1. Copy the program for back‐up purposes ONLY in support of its use on a single  ...

Page 73

... XELTEK is not responsible for the following cases:    • The product has been repaired, used, or changed by any organizations or  persons who are not authorized by XELTEK.    • The product has been damaged because of misuse or careless use.  ...

Related keywords