Chapter 5 Detail Explanations on Common Problems 
You can monitor the programmer operations through the Operation Information 
Window and message window. This chapter helps define common problems 
related to programmer actions and errors. 
Dealing with Data Files   
This section explains common problems involving the File Type dialog box.   
Solve Invalid File Type or File Data Overflow Error 
The data for programming is usually stored in the data file. Commonly used 
formats are Intel Hex, Motorola and Tektronix. The files of these formats keep data 
in text mode, which include data and address information. Because the offset 
address is not always zero, you may incur errors when loading the file directly. 
For example, the location of data in buffer (as viewed in the Edit Buffer window) 
may be incorrect or you may receive an error message when loading the file, such 
as “Invalid file type, or all file data overflow”. 
Select one of the following options to solve this problem. 
• Confirm the file type and ensure the buffer can load all the files.   
• Find the offset address of the file. When loading the file, select the Show 
Refer to the Load File section on page 28 for more information on loading files. 
Separate File Data for Programming   
By using the File Mode selection in the File Type dialog box, you can select the 
data of a file and write it to several chips of the same type. This allows you to load 
the file several times according to your needs.   
There are three methods for separating the file data. 
1. Based on byte (8bit), divide the file into two parts by the odd and even address. 
Superpro
Offset Address (Minimize) After Loading option to display the start address 
of the file after the file is loaded.   
Example: 
®
5004GP User’s Guide 
 
This means the offset address of the file is not 0. You must move the 
data at the address to the address 0 of the buffer. To do that, load the 
file again, and enter E000 as the File Address. 
File Offset Address (min): 0x0000E0000 (Hex) 
 
63 