Specifications of CB-OWS451X-04-0

Frequency
2.4GHz, 5GHz
Data Rate - Maximum
115 kbps
Modulation Or Protocol
802.11 a/b/g/n
Applications
General Purpose
Power - Output
20dBm (100mW)
Sensitivity
-89dBm
Voltage - Supply
3.3 V ~ 5.5 V
Current - Receiving
-
Current - Transmitting
-
Data Interface
Solder Pad
Memory Size
-
Antenna Connector
U.FL x 2
Operating Temperature
-40°C ~ 85°C
Package / Case
Modular
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
809-1041
connectBlue
Copyright © 2010 connectBlue AB
3.2 Pin description
J2
Pin
Nr
1,2
3,4
11
12
13
14
15
16
17
18
19
20
3.2.1 J2, J3, J6, J8 connector description
J3
Pin
Nr
8
-
-
-
-
-
-
-
-
-
-
-
6
7
9
J6
Pin
Nr
3,
25***
4
7
6
8
9
10
11
12
13
5
18,
30***
28
27
36
J8
Pin
Nr
1
2
5
5
3
6
4
-
-
-
-
-
Signal Name
VSS
VCC
RED/Mode
Switch-0
GREEN/
Switch-1
BLUE
UART-CTS*
UART-TxD*
UART-RTS*
UART-RxD*
UART-DTR*
UART-DSR*
SPI-CS0n
SPI-MOSI
SerialSelect-0 CMOS
Signal
Level
Ground Power GND
3.3 V
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
Type
Power 3.3 - 5.5 VDC power supply
Out/In
In
Out/In
Out
In
Out
Out
In
Out
In
In
In
Out
Description
This signal is multiplexed:
RED: red LED logic signal valid 600ms after power-up (see the
Operating status
Mode: Mode signal is valid as input only during the first 600ms after
startup, after that its fuction changes to red LED.
The Mode pin is active low with internal weak pull-up
Used for the "Connect on external signal" function, see the Serial Port
Adapter AT command Specification for more information on the
Function switch,
active low. The Switch-0 pin has internal weak pull-up
A secondary function is that the module will restore all factory settings if
both the Switch-1 and Switch-0 signals are low during start up.
See the Serial Port Adapter AT command Specification for more
information on the Restoring Default Configuration functionality.
See section
This signal is multiplexed:
GREEN: gren-LED logic signal valid 500ms after power-up (see the
Operating status
Switch-1: Switch-1 signal is valid as input only during the first 500ms
after power-up, after that its fuction changes to green-LED.
If this pin is pulled-down** the unit goes back to default serial settings.
The Switch-1 signal is active low with internal weak pull-up
The module will restore all factory settings if both the Switch-1 and
Switch-0 signals are pulled-down during power-up.
See the Serial Port Adapter AT command Specification for more
information on the Restoring Default Configuration functionality.
See section
Logic Blue LED Signal (see the
Active low.
Note:Blue LED will flash when data is transfered.
See section
Logic level UART Clear To Send, active low.
Logic level UART Transmit Data, "0" = Low, "1" = High
Logic level UART Request To Send, active low.
Logic level UART Receive Data, "0" = Low, "1" = High
Logic level UART Data Terminal Ready, active low.
Logic level UART Data Set Ready, active low.
Logic level SPI chip select, active low.
Logic level SPI Master Output Slave Input
Control signal for external serial transceivers.
See
Appendix Serial Interface
Switch-0 Signal
GREEN/Switch-1
BLUE Signal
section), active low.
section), active low.
for design examples.
for design examples.
for design examples
section for more info.
Operating status, table 9
Page 9 of 26
section).