MT9234ZPX-UPCI-CP Multi-Tech Systems, MT9234ZPX-UPCI-CP Datasheet - Page 50

no-image

MT9234ZPX-UPCI-CP

Manufacturer Part Number
MT9234ZPX-UPCI-CP
Description
MODEM V.92 DATA/FAX/VOICE WORLD
Manufacturer
Multi-Tech Systems
Series
MultiModem® ZPXr

Specifications of MT9234ZPX-UPCI-CP

Data Format
V.92
Baud Rates
-
Interface
Parallel
Voltage - Supply
3.3V, 5V
Mounting Type
Socket
Package / Case
6.0" L x 4.8" W x 0.7" H (152mm x 122mm x 18mm)
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
+VRA
Description:
Syntax:
Values:
Default:
Result Codes:
Reports:
+VRN
Description:
Syntax:
Values:
Values:
Default:
Result Codes:
Reports:
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H)
Ringback Goes Away Timer
Sets the length of time the modem will wait between ringbacks during a call
origination before the modem can assume that the remote device has gone off-hook.
AT+VRA=<interval>
<interval> A decimal number (0–255) specifying the silence interval time in units of
50
OK if the <interval> is 0-255.
ERROR if the <interval> parameter entered is out of range or if not in voice mode.
+VRA?
+VLS=?
Ringback Timer
Sets the length of time that the modem will wait for ringback. If the modem does not
detect a ringback within the time period <interval>, the modem assumes that the
remote device has going off-hook and returns the OK result code. The modem only
uses this command in call origination transactions. A +VRN setting greater than the
S-Register S7 setting means that only the S7 timer is in effect.
AT+VRN=<interval>
<interval> A decimal number specifying the time period in units of 1.0 seconds that
0–10 (in 1.0 second increments)
10 (10 seconds)
OK if <interval> = 0-25.
ERROR if the <interval> parameter entered is out of range or the modem is not in
voice mode.
+VRN?
+VLN=?
0.10 seconds between the end of one ring interval and the start of the
next ring interval. A value of 0 forces the modem to report the OK result
code and immediately after the first ringback. The range is 0.1 to 25.5
seconds for <interval>=1 to 255.
Displays current or selected values.
Displays a list of the supported values.
the modem will wait for ringback during a call origination. A value of 0
forces the modem to report the OK result code immediately after dialing.
The range is 1 to 25 seconds for <interval>=1 to 25.
Displays current or selected values.
Displays a list of the supported values.
Chapter 4 – Voice Commands
50