STEVAL-IPE012V1 STMicroelectronics, STEVAL-IPE012V1 Datasheet - Page 19

no-image

STEVAL-IPE012V1

Manufacturer Part Number
STEVAL-IPE012V1
Description
EVAL BOARD ENERGY METER
Manufacturer
STMicroelectronics
Series
-r

Specifications of STEVAL-IPE012V1

Design Resources
STEVAL-IPE012V1 Schematic STEVAL-IPE012V1 BOM
Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
STPM10BTR, STM8L152
Primary Attributes
Single Phase with 1 Current Transformer & Shunt
Secondary Attributes
Tamper Detection
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
497-11462
STPM10
7.6
Figure 17. Band-gap temperature variation
With the same clock frequency, if the line frequency is 130 Hz, the f
two LIN trailing edges are 8066, less than 2
f
The BFR flag is also set if the register value of the RMS voltage drops below 64. BFR is
cleared when the register value goes above 128. The BFR, then, also gives information
about the presence of the line voltage within the meter.
When the BFR error is set, the computation of power is zero unless the FRS bit is set.
In fact, the effect of the BFR bit can be overridden by setting FRS configuration bit.
It means that if FRS is set and BFR is also set, all the energy computation is carried on as
BFR was cleared. In this case then p=u*i, where u could be zero or not (if BFR was set
because voltage RMS register value is below 64).
When the line frequency re-enters the nominal band, the BFR flag is automatically reset.
This BFR error flag is also assembled as part of the 8-bit status register (see
Power supply
The main STPM10 supply pin is the VCC pin. From the VCC pin two linear regulators
provide the necessary voltage for the analog part VDDA (3 V) and for the digital part VDDD
(1.8 V).
The VSS pin represents the reference point for all the internal signals. A 100 nF low ESR
capacitor should be connected between VCC and VSS, VDDA and VSS, VDDD and VSS.
All these capacitors must be located very close to the device.
The STPM10 contains a power on reset (POR) detection circuit. If the VCC supply is less
than 2.5 V, then the STPM10 goes into an inactive state, all the functions are blocked and a
reset condition is asserted. This is useful to ensure correct device operation at power-up
and during power-down. The power supply monitor has built-in hysteresis and filtering,
which give a high degree of immunity from false triggering due to noisy supplies.
A band-gap voltage reference (VBG) of 1.23 V ±1% is used as the reference voltage level
source for the two linear regulators and for the A/D converters. Also, this module produces
several bias currents and voltages for all other analog modules. The band-gap voltage can
be compensated regardless of the temperature variations with the BGTC bits.
CLK
/2
15
= 4194304/32768 = 128 Hz.
1,29
1,29
1,28
1,28
1,27
1,27
1,26
1,26
1,25
1,25
1,24
1,24
1,23
1,23
1,22
1,22
1,21
1,21
1,20
1,20
-40
-40
Doc ID 17728 Rev 3
0
0
Temperature °C
Temperature °C
40
40
13
(8192). The BFR high frequency limit is then:
80
80
BGTC=0
BGTC=0
BGTC=1
BGTC=1
BGTC=2
BGTC=2
BGTC=3
BGTC=3
100
100
CLK
Theory of operation
/4 pulses between
Table
10).
19/51