ADUM2201BRIZ Analog Devices Inc, ADUM2201BRIZ Datasheet - Page 10

no-image

ADUM2201BRIZ

Manufacturer Part Number
ADUM2201BRIZ
Description
63T8602
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADUM2201BRIZ

No. Of Channels
2
Propagation Delay
50ns
Supply Current
2.6mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
ADuM2200/ADuM2201
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM220x are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL
Recognized under the UL 1577
component recognition program
Single protection insulation,
5000 V rms isolation voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Device considered a 2-terminal device: Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM220x is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 μA).
In accordance with DIN V VDE V 0884-10, each ADuM220x is proof-tested by applying an insulation test voltage ≥1590 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) branded on the component designates DIN V VDE V 0884-10 approval.
2
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 600 V rms (848 V peak)
maximum working voltage
Reinforced insulation per IEC 60601-1,
250 V rms (353 V peak) maximum working
voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. A | Page 10 of 20
Value
IIIa
5000
7.46 min
8.10 min
0.017 min
>175
Min
Unit
V rms 1-minute duration
mm
mm
mm
V
Typ
10
2.2
4.0
33
28
12
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
VDE
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
Reinforced insulation, 846 V peak
File 2471900-4880-0001
Max
Unit
Ω
pF
pF
°C/W
°C/W
Test Conditions
f = 1 MHz
Thermocouple located at
center of package underside
2

Related parts for ADUM2201BRIZ