GP2Y1001AU Sharp Microelectronics, GP2Y1001AU Datasheet

SENSOR AIR DUST QUALITY

GP2Y1001AU

Manufacturer Part Number
GP2Y1001AU
Description
SENSOR AIR DUST QUALITY
Manufacturer
Sharp Microelectronics
Series
-r
Type
Opticalr
Datasheet

Specifications of GP2Y1001AU

Sensitivity
1.2V/(0.1mg/m3)
Current - Dc Forward (if)
13mA
Voltage - Output
10.2V
Voltage - Supply
10.2 V ~ 13.8 V
Mounting Type
Chassis Mount
Operating Temperature
-10°C ~ 65°C
Package / Case
-
Lead Free Status / Rohs Status
Contains lead / RoHS non-compliant
Other names
425-1169
GP2Y1001AU
1. Compact, thin type (58 38 20.7mm)
2. Low dissipation current (Icc:MAX. 20mA)
3. Single-shot detection of house dust
1. Air conditioners
2. Air cleaner
*1 Open drain drive input
*1
Operating Supply voltage
Notice
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
Absolute Maximum Ratings
Supply voltage
Input terminal voltage
Operating temperature
Soldering temperature
Recommend Operating Conditions
Features
Applications
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Parameter
Parameter
Symbol
Symbol
V
V
T
V
T
LED
opr
sol
CC
CC
12 1.8
Rating
0.3 to 15
0.3 to V
10 to 65
20 to 80
Rating
CC
(Ta 25 C)
Unit
V
Unit
V
V
C
C
Compact Dust Sensor
for Air Conditioners
Outline Dimensions
R2
Unspecified tolerance : 0.3mm
Hole for
testing
8.7
5
(15.7)
22.7
through hole
29.1
6
29.1
Dust
1
9
58
Connector
JAPAN SOLDRLESS
TERMINAL MSG. CO., LTD. S6B-ZR-SM3A
Dust
through hole
10
Hole for sensitivity
adjustment volume
5
Model No.
R2
R2
GP2Y1001AU
2
configuration
1
2
3
4
5
6
Terminal
(Unit : mm)
V-LED
LED-GND
LED
S-GND
V
V
O
CC

Related parts for GP2Y1001AU

GP2Y1001AU Summary of contents

Page 1

... Air Conditioners Outline Dimensions ( 22.7 Rating Unit 0 0 (15.7) Rating Unit 5 8 Hole for testing Unspecified tolerance : 0.3mm GP2Y1001AU (Unit : mm) Model No Dust 29.1 through hole 6 1 Connector JAPAN SOLDRLESS TERMINAL MSG. CO., LTD. S6B-ZR-SM3A 29 Terminal configuration V-LED 1 LED-GND 2 LED 3 S-GND ...

Page 2

... Recommended Input Condition for LED Input Terminal Parameter Symbol Recommendation Unit Pulse cycle T P Pulse width W Conditions * 4. LED terminal 300 1 C 100 F I LED OFF I LED Output pulse 0.24ms Sampling 0.32 0.02 ms GP2Y1001AU ( Vcc 12V) MIN. TYP. MAX. Unit 0.84 1.2 1.56 V/ (0.1mg/m 0 1.2 2.5 10 10ms P 0.32ms ...

Page 3

... Fig.3 Internal Block Diagram Dust or smoke particle Fig.4 Output Voltage vs. Dust Density 0.2 0.4 0.6 Dust density (mg/m Operation LED circuit Light Amp. Amp. detector Sensitivity adjustment 0 GP2Y1001AU V-LED 3 LED 2 LED-GND Output terminal (V ) Amp S-GND Case ...

Page 4

... Personal computers --- Office automation equipment --- Telecommunication equipment [terminal] --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: --- Transportation control and safety equipment (i ...

Related keywords