AT89LP214 Atmel Corporation, AT89LP214 Datasheet - Page 40

no-image

AT89LP214

Manufacturer Part Number
AT89LP214
Description
Manufacturer
Atmel Corporation
Datasheet

Specifications of AT89LP214

Flash (kbytes)
2 Kbytes
Max. Operating Frequency
20 MHz
Cpu
8051-1C
Max I/o Pins
12
Spi
1
Uart
1
Sram (kbytes)
0.125
Operating Voltage (vcc)
2.4 to 5.0
Timers
2
Isp
SPI/OCD
Watchdog
Yes
Table 17-1.
Notes:
40
SCON Address = 98H
Bit Addressable
Bit
Symbol
FE
SM0
SM1
SM2
REN
TB8
RB8
TI
RI
(SMOD0 = 0/1)
1. SMOD0 is located at PCON.6.
2. f
AT89LP213/214
SM0/FE
osc
Function
Framing error bit. This bit is set by the receiver when an invalid stop bit is detected. The FE bit is not cleared by valid
frames and must be cleared by software. The SMOD0 bit must be set to enable access to the FE bit. FE will be set
regardless of the state of SMOD0.
Serial Port Mode Bit 0, (SMOD0 must = 0 to access bit SM0)
Serial Port Mode Bit 1
Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then Rl will not be set unless the received
9th data bit (RB8) is 1, indicating an address, and the received byte is a Given or Broadcast Address. In Mode 1, if SM2 =
1 then Rl will not be activated unless a valid stop bit was received, and the received byte is a Given or Broadcast Address.
In Mode 0, SM2 should be 0.
Enables serial reception. Set by software to enable reception. Clear by software to disable reception.
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as desired.
In Modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop bit that was received. In Mode
0, RB8 is not used.
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the beginning of the stop bit in the
other modes, in any serial transmission. Must be cleared by software.
Receive interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or halfway through the stop bit time in the
other modes, in any serial reception (except see SM2). Must be cleared by software.
7
SCON – Serial Port Control Register
= oscillator frequency.
SM0
0
0
1
1
(1)
bit and prepares to receive the data bytes that follows. The slaves that are not addressed set
their SM2 bits and ignore the data bytes.
The SM2 bit has no effect in Mode 0 but can be used to check the validity of the stop bit in
Mode 1. In a Mode 1 reception, if SM2 = 1, the receive interrupt is not activated unless a valid
stop bit is received.
SM1
6
SM1
0
1
0
1
SM2
5
Mode
0
1
2
3
REN
4
Description
shift register
8-bit UART
9-bit UART
9-bit UART
TB8
See “Automatic Address Recognition” on page
3
variable (Timer 1)
variable (Timer 1)
RB8
f
osc
Baud Rate
2
/32 or f
f
osc
/2
osc
(2)
Reset Value = 0000 0000B
/16
T1
1
3538E–MICRO–11/10
RI
0
49.

Related parts for AT89LP214