STR712FR2 STMicroelectronics, STR712FR2 Datasheet - Page 49
STR712FR2
Manufacturer Part Number
STR712FR2
Description
ARM7TDMI™ 16/32-BIT MCU WITH FLASH, USB, CAN, 5 TIMERS, ADC, 10 COMMUNICATIONS INTERFACES
Manufacturer
STMicroelectronics
Datasheet
1.STR711FR0.pdf
(78 pages)
Specifications of STR712FR2
5 Power Saving Modes
SLOW, WAIT, LPWAIT, STOP and STANDBY modes
Conversion Range
0 to 2.5 V
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
STR712FR2H6
Manufacturer:
SMSC
Quantity:
1 001
Company:
Part Number:
STR712FR2H6
Manufacturer:
STMicroelectronics
Quantity:
10 000
Company:
Part Number:
STR712FR2T6
Manufacturer:
STMicroelectronics
Quantity:
1 882
Company:
Part Number:
STR712FR2T6
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STR712FR2T6
Manufacturer:
ST
Quantity:
20 000
STR71xF
Table 27.
Notes:
1. Data based on characterization results, not tested in production.
Static and dynamic latch-up
●
●
Electrical sensitivities
Table 28.
1. Class description: A Class is an STMicroelectronics internal specification. All its limits are higher than the
V
V
V
Symbol
Symbol
ESD(CDM)
ESD(HBM)
ESD(MM)
JEDEC specifications, that means when a device belongs to Class A it exceeds the JEDEC standard. B
Class strictly covers all the JEDEC criteria (international standard).
DLU
LU
LU: 3 complementary static tests are required on 10 parts to assess the latch-up
performance. A supply overvoltage (applied to each power supply pin) and a current
injection (applied to each input, output and configurable I/O pin) are performed on each
sample. This test conforms to the EIA/JESD 78 IC latch-up standard. For more details,
refer to the application note AN1181.
DLU: Electro-Static Discharges (one positive then one negative test) are applied to
each pin of 3 samples when the micro is running to assess the latch-up performance in
dynamic mode. Power supplies are set to the typical values, the oscillator is connected
as near as possible to the pins of the micro and the component is put in reset mode.
This test conforms to the IEC1000-4-2 and SAEJ1752/3 standards. For more details,
refer to the application note AN1181.
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
Electro-static discharge voltage
(Charge Device Model)
Static latch-up class
Dynamic latch-up class
ESD absolute maximum ratings
Static and dynamic latch-up
Parameter
Ratings
T
T
T
V
T
A
A
A
A
DD
=+25°C
=+85°C
=+105°C
=+25°C
=3.3 V, f
T
A
OSC4M
=+25°C
Conditions
Conditions
=4 MHz, f
MCLK
=32 MHz,
Electrical parameters
750 on corner
pins, 500 on
Maximum
value
others
2000
200
1)
Class
A
A
A
A
Unit
(1)
49/78
V