ST92150JDV1TAuto STMicroelectronics, ST92150JDV1TAuto Datasheet - Page 415

no-image

ST92150JDV1TAuto

Manufacturer Part Number
ST92150JDV1TAuto
Description
8-bit MCU for automotive
Manufacturer
STMicroelectronics
Datasheet

Specifications of ST92150JDV1TAuto

Internal Memory
Single Voltage FLASH up to 256 Kbytes, RAM up to 8Kbytes, 1K byte E3 TM (Emulated EEPROM)
Minimum Instruction Time
83 ns (24 MHz int. clock)
KNOWN LIMITATIONS (Cont’d)
13.6 CAN FIFO CORRUPTION WHEN 2 FIFO MESSAGES ARE PENDING
Description
Under certain conditions, FIFO corruption can
occur in the following cases:
WHEN a bxCAN RX FIFO already holds 2 mes-
sages (i.e. FMP==2)
Figure 168. FIFO Corruption
and Receive Message D
AND the application releases the same FIFO
Receive Message C
Release Message A
Release Message B
Release Message C
Release Message E
Release Message B
Receive Message A
Receive Message B
Receive Message E
(with the instruction CANx_CTRL_CRFRy |=
CRF_rfom;
x=0 for the CAN_0 cell
x=1 for the CAN_1 cell
y=0 for the Receive FIFO 0
y=1 for the Receive FIFO 1 )
* pointer to next receive location
v pointer to next message to be released
Initial State
FMP
0
1
2
3
2
2
3
2
1
0
v
E B C
v
* v
- - -
A - -
v
A B -
v
A B C
E B C
E B C
E B C
A B C
D B C
D B C
*
FIFO
*
*
v
* v
*
*
* v
v
*
*
*
v
v
When the FIFO is empty, v and * point to the same location
E released instead of B
* does not move because FIFO is full (normal operation)
D is overwritten by E
C released
* and v are not pointing to the same message
the FIFO is empty
* Does not move, pointer curruption
Normal operation
ST92124xxx-Auto/150xxxxx-Auto/250xxxx-Auto
WHILE the bxCAN requests the transfer of a new
receive message into the FIFO (this lasts one CPU
cycle)
Impact on Application:
As the FIFO pointer is not updated correctly, this
causes the last message received to be over-
written by any incoming message. This means one
message is lost as shown in the example in
168
until a device reset occurs.
THEN the internal FIFO pointer is not updated
BUT the FMP bits are updated correctly
The bxCAN will not recover normal operation
415/430
Figure
1

Related parts for ST92150JDV1TAuto