71M6511 Maxim, 71M6511 Datasheet - Page 33

no-image

71M6511

Manufacturer Part Number
71M6511
Description
The 71M6511 and 71M6511H are highly integrated SoCs with an MPU core, RTC, flash, and LCD driver
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6511-IGT
Manufacturer:
TERIDIA
Quantity:
20 000
Part Number:
71M6511-IGT/F
Manufacturer:
ST
Quantity:
1 500
Part Number:
71M6511-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511H-IGT/F
Manufacturer:
PERICOM
Quantity:
1 200
Part Number:
71M6511H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6511H-IGTR/F
Manufacturer:
MAXIM
Quantity:
101
Part Number:
71M6511H-IGTR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
XFER_BUSY and RTC_1SEC, which are OR-ed together, have their own enable and flag bits in addition to the interrupt 6
enable and flag bits (see Table 45), and these interrupts must be cleared by the MPU software.
Interrupt 6 is edge-sensitive. The RTC_1SEC interrupt from the RTC and the XFER_BUSY interrupt from the CE are com-
bined using a logic OR function and the result is routed into interrupt 6. Therefore, both flags must be cleared at least once
during initialization, and both flags must always be cleared before exiting the interrupt service routine (ISR) for interrupt 6.
Note 1: If clearing of both flags is not performed, then no edge can occur to trigger interrupt 6 later resulting in the ISR for the
XFER_BUSY ceasing to run.
Note 2: Clearing both flags reliably requires some care. Either flag can be set by hardware while interrupt 6 code is running on
behalf of the other interrupt. In this situation, the unprocessed interrupt can create a lockout condition similar to the one in note
1. To prevent this lockout one must always process both interrupt flags in the same service routine.
Note 3: After a reset from an in-circuit emulator, the IE_XFER flag may not be cleared because the CE may continue to run.
The flags for the RTC_1SEC and the XFER_BUSY interrupts are located in the WDI SFR (address 0xE8).
Page: 33 of 98
Enable Bit
Interrupt
External
A Maxim Integrated Products Brand
EX_XFER
EX_RTC
EX0
EX1
EX2
EX3
EX4
EX5
EX6
Connection
Description
Enable external interrupt 0
Enable external interrupt 1
Enable external interrupt 2
Enable external interrupt 3
Enable external interrupt 4
Enable external interrupt 5
Enable external interrupt 6
Enable XFER_BUSY interrupt
Enable RTC_1SEC interrupt
0
1
2
3
4
5
6
Digital I/O High Priority
Digital I/O Low Priority
Comparator 2 or 3
CE_BUSY
Comparator 2 or 3
EEPROM busy
XFER_BUSY OR RTC_1SEC
Table 45: Control Bits for External Interrupts
© 2005–2010 Teridian Semiconductor Corporation
Table 44: External MPU Interrupts
Polarity
Flag Bit
Single-Phase Energy Meter IC
IE_XFER
IE_RTC
IEX2
IEX3
IEX4
IEX5
IEX6
IE0
IE1
see DIO_Rx
see DIO_Rx
Flag Reset
71M6511/71M6511H
Description
falling
falling
falling
falling
rising
DATA SHEET
External interrupt 0 flag
External interrupt 1 flag
External interrupt 2 flag
External interrupt 3 flag
External interrupt 4 flag
External interrupt 5 flag
External interrupt 6 flag
XFER_BUSY interrupt flag
RTC_1SEC interrupt flag
automatic
automatic
automatic
automatic
automatic
automatic
manual
NOVEMBER 2010
V2.7

Related parts for 71M6511