Specifications of LMH1983SQ/NOPB

Applications
Video Equipment
Mounting Type
Surface Mount
Package / Case
40-LLP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Video and Audio Clock Outputs (CLKout1, CLKout2 and CLKout3)
t
D1
Symbol
(Note
t
t
t
t
t
D2
D3
D4
DJ
RJ
8) Timing output delay time
Timing output delay time
Timing output delay time
Timing output delay time
27 MHz TIE deterministic Jitter Measured at CLKout1 all other CLKouts
148.5 MHz TIE deterministic
Jitter
148.35 MHz TIE deterministic
Jitter
24.576 MHz TIE deterministic
Jitter
27 MHz TIE random Output
Jitter
148.5 MHz TIE Random Output
Jitter
148.35 MHz TIE Random
Output Jitter
24.576 MHz TIE Random
Output Jitter
(Note
(Note
Parameter
7)
7)
(Note
(Note
7)
7)
TOF1 delay measured from the CLKout1
clock reset edge. Delay spec applies for all
output clock and format supported by the
output pair following output initialization. 15
pF load.
TOF2 delay measured from the CLKout2
clock reset edge. Delay spec applies for all
output clock and format supported by the
output pair following output initialization. 15
pF load.
TOF3 delay measured from the CLKout3
clock reset edge. Delay spec applies for all
output clock and format supported by the
output pair following output initialization. 15
pF load.
TOF4 delay measured from the CLKout4
clock reset edge. Delay spec applies for all
output clock and format supported by the
output pair following output initialization. 15
pF load.
shutdown
Measured at CLKout1, other CLKouts
output default PLL
Measured at CLKout2 all other CLKouts
shutdown
Measured at CLKout2, other CLKouts
output default PLL
Measured at CLKout3 all other CLKouts
shutdown
Measured at CLKout3, other CLKouts
output default PLL
Measured at CLKout4 all other CLKouts
shutdown
Measured at CLKout4, other CLKouts
output default PLL
Measured at CLKout1, other CLKouts
shutdown
Measured at CLKout1, other CLKouts
output default PLL
Measured at CLKout2, other CLKouts
shutdown
Measured at CLKout2, other CLKouts
output default PLL
Measured at CLKout3, other CLKouts
shutdown
Measured at CLKout3, other CLKouts
output default PLL
Measured at CLKout4, other CLKouts
shutdown
Measured at CLKout4, other CLKouts
output default PLL
Conditions
7
(Note
Min
6)
(Note
Typ
250
250
2.7
2.7
3.0
3.0
3.5
3.5
3.4
3.4
22
22
15
15
2
2
8
8
4
4
5)
(Note
Max
www.national.com
6)
Units
ns
ns
ns
ns
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
ps
fs
fs