APL111-23486-2

Manufacturer Part Number
APL111-23486-2
Description
Circuit Breaker, Magnetic Circuit Breakers
Manufacturer
Airpax Corporation
Datasheet
148
How to Order
The ordering code for 205/295 circuit breakers may be
determined by following the steps in the decision tables
shown here.
recognized, two pole breaker with series trip, 20 ampere
rating at 240Vac max., 50/60Hz short time delay construc-
tion in all poles.
205/295 unit, simply follow the steps shown. You may use
this number to place an order or as a reference for further
questions you may have.
Notes:
A The most common current values for 100% of rated current are those listed.
B All 205/295 breakers are constructed with stainless steel springs and
C Terminals will be supplied as #10-32 threaded studs up to 50 amperes.
205/295 Decision Tables
*Use 0 in place of 1 when ordering switch only.
205
205D
295
-0*
-1
-11
-111
-1111
1
205/295 DECISION TABLES
2
For example, the code shown is the code for a UL
To determine the ordering number for your particular
Please consult an Airpax office or sales representative for other values.
plated parts. As noted in the specifications, all meet normal requirements
for moisture and salt spray resistance. If fungus resistance is required in
addition to moisture and salt spray resistance, special procedures and
markings are employed.
Above this amperage terminals will be ⁄/¢-28 threaded studs. All standard
units will be supplied with a hex nut and 2 flat washers on each
threaded terminal.
First
Type
Second Decision
Poles
Decision
Switch only (no overload sensing)
Single pole unit
Two pole unit
Three pole unit
Four pole unit
Dust sealed breaker UL
ratings and construction
Marine ignition protected
Dust sealed breaker
D For detailed barrier and wiring information, request Airpax
E When metric threaded inserts are specified, breakers rated at 50 amperes
F Available in multi-pole, series only for multiphase applications.
specification AM-433.
and below will be supplied with metric threaded terminals. For breakers
rated above 50 amperes, ⁄/¢-28 threaded terminals will be supplied.
Multi-pole units with mixed construction, poles numbered left
to right when viewed from terminal end.
*Can be used for Solder Terminals also.
-0
-1
-1REC4
-1REC5
-1REG4
-1RS
-3
-5
3
Example:
Third Decision
Internal Configuration
205 - 11 - 1 - 61- 4 - 203
1
2
Switch only
(Omit 4th and 5th decisions)
Series
Series with auxiliary switch
*.110 quick connect terminals
Series wtih auxiliary switch
*.187 quick connect terminals
Series with auxiliary switch
(gold contacts) *.110 quick
connect terminals
Series with alarm switch
electrical trip turret terminals
Shunt
Relay
3
4 5
6