MDO4054-3GSA Tektronix, MDO4054-3GSA Datasheet - Page 16

no-image

MDO4054-3GSA

Manufacturer Part Number
MDO4054-3GSA
Description
Specifications: Scope Type: Bench ; Scope Channels: 4 Analogue + 16 Digital + 1 RF ; Bandwidth: 500MHz ; Meter Display Type: XGA TFT-LCD Color ; Sampling Rate: 2.5GSPS ; Input Impedance: 1Mohm ; Rise Time: 700ps ; Input Voltage: 300Vrms ; Supply Volt
Manufacturer
Tektronix
Datasheet
Data Sheet
Waveform Math
Characteristic
Arithmetic
Math Functions
FFT
Spectrum Math
Advanced Math
Power Measurements (Optional)
Measurement
Power Quality
Measurements
Switching Loss
Measurements
Harmonics
Ripple
Measurements
Modulation Analysis
Safe Operating Area
dV/dt and dI/dt
Measurements
16
www.tektronix.com
Description
Add, subtract, multiply, and divide waveforms
Integrate, Differentiate, FFT
Spectral magnitude
FFT Vertical Scale: Linear RMS or dBV RMS
FFT Window Settings: Rectangular, Hamming,
Hanning, Blackman Harris
Add or subtract frequency domain traces
Define extensive algebraic expressions including
waveforms, reference waveforms, math functions.
Perform math on math using complex equations
(FFT, Intg, Diff, Log, Exp, Sqrt, Abs, Sine,
Cosine, Tangent, Rad, Deg), scalars, up to two
user-adjustable variables and results of parametric
measurements (Period, Freq, Delay, Rise,
Fall, PosWidth, NegWidth, BurstWidth, Phase,
PosDutyCycle, NegDutyCycle, PosOverShoot,
NegOverShoot, PeakPeak, Amplitude, RMS,
CycleRMS, High, Low, Max, Min, Mean,
CycleMean, Area, CycleArea, and trend plots)
e.g. (Intg(Ch1–Mean(Ch1))×1.414×VAR1)
Description
V
Power, Apparent Power, Reactive Power, Power
Factor, Phase Angle
Power Loss: T
Energy Loss: T
THD-F, THD-R, RMS measurements
Graphical and table displays of harmonics
Test to IEC61000-3-2 Class A and MIL-STD-1399
Section 300A
V
Graphical display of +Pulse Width, –Pulse Width,
Period, Frequency, +Duty Cycle, and –Duty Cycle
modulation types
Graphical display and mask testing of switching
device safe operating area measurements
Cursor measurements of slew rate
RMS
ripple
, V
and I
Crest Factor
ripple
on
, Frequency, I
on
, T
, T
off
off
, Conduction, Total
, Conduction, Total
RMS
, I
Crest Factor
, True
Limit/Mask Testing (Optional)
Software
Characteristic
Included Standard Masks ITU-T, ANSI T1.102, USB
Test Source
Mask Creation
Mask Scaling
Test Criteria Run Until
Violation Threshold
Actions on Test Failure
Actions on Test Complete Trigger out pulse, set remote interface SRQ
Results Display
Software
NI LabVIEW
SignalExpress Tektronix
Edition
OpenChoice
IVI Driver
e*Scope
Remote Control
LXI Class C
Web Interface
®
Web-based
®
Desktop
Description
Limit Test: Any Ch1 - Ch4 or any R1 - R4
Mask Test: Any Ch1 - Ch4
Limit test vertical tolerance from 0 to 1 division in 1 m
division increments; Limit test horizontal tolerance from
0 to 500 m division in 1 m division increments
Load standard mask from internal memory
Load custom mask from text file with up to 8 segments
Lock to Source ON (mask automatically re-scales with
source-channel settings changes)
Lock to Source OFF (mask does not re-scale with
source-channel settings changes)
Minimum number of waveforms (from 1 to 1,000,000;
Infinity)
Minimum elapsed time (from 1 second to 48 hours;
Infinity)
From 1 to 1,000,000
Stop acquisition, save screen image to file, save
waveform to file, print screen image, trigger out pulse,
set remote interface SRQ
Test status, total waveforms, number of violations,
violation rate, total tests, failed tests, test failure rate,
elapsed time, total hits for each mask segment
Description
A fully interactive measurement software environment
optimized for the MDO4000 Series, enables you to
instantly acquire, generate, analyze, compare, import,
and save measurement data and signals using an
intuitive drag-and-drop user interface that does not
require any programming.
Standard MDO4000 Series support for acquiring,
controlling, viewing, and exporting your live signal data
is permanently available through the software. The full
version (SIGEXPTE) adds additional signal processing,
advanced analysis, mixed signal, sweeping, limit
testing, and user-defined step capabilities and is
available for a 30-day trial period standard with each
instrument.
Enables fast and easy communication between a
Windows PC and the MDO4000 Series, using USB
or LAN. Transfer and save settings, waveforms,
measurements, and screen images. Included Word
and Excel toolbars automate the transfer of acquisition
data and screen images from the oscilloscope into
Word and Excel for quick reporting or further analysis.
Provides a standard instrument programming
interface for common applications such as LabVIEW,
LabWindows/CVI, Microsoft .NET and MATLAB.
Enables control of the MDO4000 Series over a
network connection through a standard web browser.
Simply enter the IP address or network name of the
oscilloscope and a web page will be served to the
browser.
Connect to the MDO4000 Series through a standard
web browser by simply entering the oscilloscope's
IP address or network name in the address bar of
the browser. The web interface enables viewing
of instrument status and configuration, status and
modification of network settings, and instrument control
through the e*scope web-based remote control. All web
interaction conforms to LXI Class C specification.

Related parts for MDO4054-3GSA