XR16L580 Exar Corporation, XR16L580 Datasheet - Page 29

no-image

XR16L580

Manufacturer Part Number
XR16L580
Description
Smallest 2.25 to 5.5V Uart With 16-Byte Fifo And Power-save
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR16L580IL-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Company:
Part Number:
XR16L580IL-F
Quantity:
15 000
Part Number:
XR16L580IL-FN
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Part Number:
XR16L580IL24-F
Manufacturer:
EXAR
Quantity:
1 975
Part Number:
XR16L580IL24-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
XR16L580ILTR-F
Quantity:
5 000
Part Number:
XR16L580IM-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XR16L580IM-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Part Number:
XR16L580IMTR-F
Manufacturer:
Exar Corporation
Quantity:
10 000
áç
áç
áç
áç
REV. 1.2.0
MCR[3]: INT Output Enable or OP2# (legacy term)
This bit enables and disables the operation of interrupt output, INT in the Intel mode. It has no function in the
Motorola mode.
In the Internal Loopback Mode, this bit functions like the OP2# in the 16C550 and is used to set the state of the
modem input CD# bit in the MSR register.
MCR[4]: Internal Loopback Enable
MCR[5]: Xon-Any Enable
MCR[6]: Infrared Encoder/Decoder Enable
MCR[7]: BRG Clock Prescaler Select
This register provides the status of data transfers between the UART and the host.
LSR[0]: Receive Data Ready Indicator
LSR[1]: Receiver Overrun Flag
LSR[2]: Receive Data Parity Error Flag
4.9
Logic 0 = INT output disabled (three state mode) (default).
Logic 1 = INT output enabled (active mode).
Logic 0 = Disable loopback mode (default).
Logic 1 = Enable local loopback mode, see loopback section and
Logic 0 = Disable Xon-Any function (for 16C550 compatibility, default).
Logic 1 = Enable Xon-Any function. In this mode, any RX character received will resume transmit operation. The
RX character will be loaded into the RX FIFO, unless the RX character is an Xon or Xoff character and the L580 is
programmed to use the Xon/Xoff flow control.
Logic 0 = Enable the standard modem receive and transmit input/output interface (default).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. The TX/RX output/input are routed to the
infrared encoder/decoder. The data input and output levels conform to the IrDA infrared interface requirement.
While in this mode, the infrared TX output will be a logic 0 during idle data conditions.
Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable Baud
Rate Generator without further modification, i.e., divide by one (default).
Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and feeds it
to the Programmable Baud Rate Generator, hence, data rates get reduced 4 times.
Logic 0 = No data in receive holding register or FIFO (default).
Logic 1 = Data has been received and is saved in the receive holding register or FIFO.
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens when
additional data arrives while the FIFO is full. In this case the previous data in the receive shift register is
overwritten. Note that under this condition the data byte in the receive shift register is not transferred into the FIFO,
therefore the data in the FIFO is not corrupted by the error.
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect. This
error is associated with the character available for reading in RHR.
Line Status Register (LSR) - Read Only
SMALLEST 2.25V TO 5.5V UART WITH 16-BYTE FIFO AND POWERSAVE
29
Figure 13
.
XR16L580