HD44780U Hitachi Semiconductor (acquired by Renesas), HD44780U Datasheet - Page 40

no-image

HD44780U

Manufacturer Part Number
HD44780U
Description
Dot Matrix Liquid Crystal Display Controller/driver
Manufacturer
Hitachi Semiconductor (acquired by Renesas)
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD44780UA00FS
Manufacturer:
HITACHI/日立
Quantity:
20 000
HD44780U
Instruction and Display Correspondence
Note: When using the internal reset, the electrical characteristics in the Power Supply Conditions Using
206
8-bit operation, 8-digit
Refer to Table 11 for an example of an 8-digit 1-line display in 8-bit operation. The HD44780U
functions must be set by the function set instruction prior to the display. Since the display data RAM
can store data for 80 characters, as explained before, the RAM can be used for displays such as for
advertising when combined with the display shift operation.
Since the display shift operation changes only the display position with DDRAM contents unchanged,
the first display data entered into DDRAM can be output when the return home operation is
performed.
4-bit operation, 8-digit
The program must set all functions prior to the 4-bit operation (Table 12). When the power is turned
on, 8-bit operation is automatically selected and the first write is performed as an 8-bit operation.
Since DB0 to DB3 are not connected, a rewrite is then required. However, since one operation is
completed in two accesses for 4-bit operation, a rewrite is needed to set the functions (see Table 12).
Thus, DB4 to DB7 of the function set instruction is written twice.
8-bit operation, 8-digit
For a 2-line display, the cursor automatically moves from the first to the second line after the 40th
digit of the first line has been written. Thus, if there are only 8 characters in the first line, the
DDRAM address must be again set after the 8th character is completed. (See Table 13.) Note that the
display shift operation is performed for the first and second lines. In the example of Table 13, the
display shift is performed when the cursor is on the second line. However, if the shift operation is
performed when the cursor is on the first line, both the first and second lines move together. If the
shift is repeated, the display of the second line will not move to the first line. The same display will
only shift within its own line for the number of times the shift is repeated.
Internal Reset Circuit table must be satisfied. If not, the HD44780U must be initialized by
instructions. See the section, Initializing by Instruction.
1-line display with internal reset
1-line display with internal reset
2-line display

Related parts for HD44780U