MC705P6A Motorola, MC705P6A Datasheet - Page 44

no-image

MC705P6A

Manufacturer Part Number
MC705P6A
Description
Microcontrollers
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC705P6ACDWE
Manufacturer:
Freescale Semiconductor
Quantity:
135
Part Number:
MC705P6ACDWE
Manufacturer:
FREESCALE
Quantity:
2 200
Part Number:
MC705P6ACDWE
Manufacturer:
FREESCALE
Quantity:
2 200
Part Number:
MC705P6ACDWE
Manufacturer:
MOT
Quantity:
1 000
Part Number:
MC705P6ACDWE
Manufacturer:
MOT
Quantity:
1 000
Part Number:
MC705P6ACDWE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC705P6ACDWE
0
Company:
Part Number:
MC705P6ACDWE
Quantity:
500
Company:
Part Number:
MC705P6ACDWE
Quantity:
466
Part Number:
MC705P6ACPE
Manufacturer:
SMC
Quantity:
2 100
Part Number:
MC705P6ACPE
Manufacturer:
FREESCAL
Quantity:
1 183
Part Number:
MC705P6ACPE
Manufacturer:
FREESCA
Quantity:
3 437
Part Number:
MC705P6ACPE
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
MC705P6ACPE
Quantity:
1 100
Part Number:
MC705P6AMDWE
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MC705P6AMPE
Manufacturer:
Freescale Semiconductor
Quantity:
135
Serial Input/Output Port (SIOP)
7.3.2 SIOP Status Register (SSR)
This register is located at address $000B and contains two bits.
in the register and indicates the value of each bit after reset.
SPIF — Serial Port Interface Flag
DCOL — Data Collision
7.3.3 SIOP Data Register (SDR)
This register is located at address $000C and serves as both the transmit and receive data register.
Writing to this register will initiate a message transmission if the SIOP is in master mode. The SIOP
subsystem is not double buffered and any write to this register will destroy the previous contents. The
SDR can be read at any time; however, if a transfer is in progress, the results may be ambiguous and the
DCOL bit will be set. Writing to the SDR while a transfer is in progress can cause invalid data to be
transmitted and/or received.
affected by reset.
44
SPIF is a read-only status bit that is set on the last rising edge of SCK and indicates that a data transfer
has been completed. It has no effect on any future data transfers and can be ignored. The SPIF bit is
cleared by reading the SSR followed by a read or write of the SDR. If the SPIF is cleared before the
last rising edge of SCK, it will be set again on the last rising edge of SCK. Reset clears the SPIF bit.
DCOL is a read-only status bit which indicates that an illegal access of the SDR has occurred. The
DCOL bit will be set when reading or writing the SDR after the first falling edge of SCK and before SPIF
is set. Reading or writing the SDR during this time will result in invalid data being transmitted or
received.
The DCOL bit is cleared by reading the SSR (when the SPIF bit is set) followed by a read or write of
the SDR. If the last part of the clearing sequence is done after another transfer has started, the DCOL
bit will be set again. Reset clears the DCOL bit.
Address:
Address:
Reset:
Reset:
Read:
Read:
Write:
Write:
$000B
$000C
SPIF
Bit 7
Bit 7
SD7
0
MC68HC705P6A Advance Information Data Sheet, Rev. 2.1
Figure 7-5
Figure 7-5. Serial Port Data Register (SDR)
= Unimplemented
Figure 7-4. SIOP Status Register (SSR)
DCOL
SD6
6
0
6
shows the position of each bit in the register. This register is not
SD5
5
0
0
5
Unaffected by reset
SD4
4
0
0
4
SD3
3
0
0
3
Figure 7-4
SD2
2
0
0
2
shows the position of each bit
SD1
1
0
0
1
Freescale Semiconductor
Bit 0
Bit 0
SD0
0
0