upd6133 Renesas Electronics Corporation., upd6133 Datasheet - Page 23

no-image

upd6133

Manufacturer Part Number
upd6133
Description
4-bit Single-chip Microcontroller For Infrared Remote Control Transmission
Manufacturer
Renesas Electronics Corporation.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD6133
Manufacturer:
KODENSHI
Quantity:
1
Part Number:
upd6133-488
Manufacturer:
NEC
Quantity:
634
Part Number:
upd6133-488
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd61333AF1-323-RNB-A
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
upd61333AF1-323-RNB-A
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
upd61333AF1-323-RNB-A
Quantity:
51
Part Number:
upd61333AF1-323RNB-A
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
upd61333F1-RNB-SSA-A
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd61335F-237-RNB
Manufacturer:
NEC
Quantity:
20 000
Part Number:
upd61335F1-237-RNB-A
Manufacturer:
RENESAS
Quantity:
20 013
Part Number:
upd61335F1-237-RNB-A
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
upd6133G-445-T2
Manufacturer:
NEC
Quantity:
30 500
Part Number:
upd6133GS-403-E1
Manufacturer:
NEC
Quantity:
24 000
Part Number:
upd6133GS-524
Manufacturer:
NEC
Quantity:
1 000
Part Number:
upd6133GS-525
Manufacturer:
NEC
Quantity:
1 000
5.2 Standby Mode Setup and Cancelation
standby mode to be set, the status flag (F) is required to have been cleared (to 0).
the operand of HALT instruction. If the standby mode is canceled, the status flag (F) is set (to 1).
mode is not set. If the cancelation condition is not met at this time, the status flag is cleared (to 0). If the cancelation
condition is met, the status flag remains set (to 1).
is executed, the standby mode is not set. Here, also, the status flag (F) is set (to 1).
The standby mode is set with the HALT #b
The standby mode is canceled by the cancelation condition specified with the RESET (RESET input; POC) or
Even when the HALT instruction is executed in the state that the status flag (F) has been set (to 1), the standby
Even in the case when the cancelation condition has been already met at the point that the HALT instruction
Caution Depending on the status of the status flag (F), the HALT instruction may not be executed. Be
Example
careful about this. For example, when setting HALT mode after checking the key status with
the STTS instruction, the system does not enter HALT mode as long as the status flag (F)
remains set (to 1) thus sometimes performing an unintended operation. In this case, the
intended operation can be realized by executing the STTS instruction immediately after timer
setting to clear (to 0) the status flag.
Reset
Cancelation condition shown in Table 5-3
Table 5-2. Addresses Executed After Standby Mode Release
Cancelation Condition
STTS
MOV
STTS
HALT
#03H
T, #0xxH
#05H
(During this time, be sure not to execute an instruction that may set the status flag.)
#05H
Data Sheet U10454EJ6V0DS00
3
;To check the K
;To set the timer
;To clear the status flag
;To set HALT mode
b
2
b
1
b
0
B instruction for both STOP mode and HALT mode. For the
0 address
The address following the HALT instruction
I
Address Executed After Cancelation
pin status.
PD6133, 6134
23

Related parts for upd6133