Single Loop Controller
Manufacturer
Yamatake Corporation
Datasheet
Event
Event type
.
G shows that the ON/
OFF is changed at
this value.
shows that the ON/
OFF is changed at
a point that "1U" is
added to this value.
The event is turned ON when any change in PV corresponding to increase/decrease in MV (Manipulated
variable) is not observed.
This event is used to detect any fault of final control devices.
G Setting items
G Operation specifications
G CAUTION
Heat control
ON if PV alarm (alarm code AL01 to 03) occurs,
OFF in other cases.
ON in the READY mode.
OFF in the RUN mode.
ON in the MANUAL mode.
OFF in the AUTO mode.
ON while AT is running.
OFF while AT is being stopped.
ON during SP ramp.
OFF when SP ramp is not performed or is completed. ON when SP ramp is not performed or is completed.
ON during direct action (cooling).
OFF during reverse action (heating).
ON during estimated position control.
OFF in other cases.
PV to be
used as
reference
Upper
Lower
• Main setting: Change in PV from the point that the MV reaches the upper limit (100%) or lower limit (0%).
• Sub-setting: Range of absolute value of deviation (PV – SP) allowing the event to turn OFF.
• ON delay time: Diagnosis time
• OFF delay time: A period of time from power ON allowing the event to turn OFF.
• The direct action is used for the heat control. The event is turned ON when the increase in PV becomes
• The reverse action is used for the cool control. The event is turned ON when the decrease in PV becomes
• The event is turned OFF regardless of other conditions when the absolute value of the deviation (PV – SP)
• The event is turned OFF regardless of other conditions when a period of time after starting of operation
When setting the ON delay and OFF delay, it is necessary to put in "Multi-function setup".
The default settings of the ON delay and OFF delay before shipment are 0.0s.
limit
limit
smaller than the main setting after the diagnosis time (ON delay time) has elapsed from the time that the MV
had reached the upper limit, or when the decrease in PV becomes smaller than the main setting from the
time that the diagnosis time (ON delay time) has elapsed from the time that the MV had reached the lower limit.
smaller than the main setting after the diagnosis time (ON delay time) has elapsed from the time that the
MV had reached the upper limit, or when the increase in PV becomes smaller than the main setting after
the diagnosis time (ON delay time) has elapsed from the time that the MV had reached the lower limit.
becomes less than the sub-setting.
from the time that the power has been turned ON becomes less than the OFF delay time.
However, the event is turned OFF when the absolute value of the deviation is the (sub-setting – hysteresis)
value or less after the absolute value of the deviation has become the sub-setting or more.
MV
PV
EV
ON delay is started when conditions 1 and 2 are satisfied.
Conditions 3
Area satisfying
conditions 2
ON delay
set time
Area satisfying
conditions 2
Direct action
ON
Direct action
Direct action
Direct action
Direct action
Direct action
Direct action
Direct action
HYS
Main setting (0 or more)
PV to be used
Conditions 3
as reference
ON delay
Area satisfying
conditions 2
set time
During motor opening estimation (status)
Area satisfying
conditions 2
5
ON
Control operation (status)
During AT (Auto tuning)
HYS
(0 or more)
Time
Time
Time
Main
setting
Loop diagnosis 3
PV alarm (status)
MANUAL (status)
During SP ramp
READY (status)
Cool control
OFF if PV alarm (alarm code AL01 to 03) occurs,
ON in other cases.
OFF in the READY mode.
ON in the RUN mode.
OFF in the MANUAL mode.
ON in RUN mode.
OFF while AT is running.
ON while AT is being stopped.
OFF during SP ramp.
OFF during direct action (cooling).
ON during reverse action (heating).
OFF during estimated position control.
ON in other cases.
Upper
Lower
PV to be
used as
reference
limit
limit
MV
PV
EV
ON delay is started when conditions 1 and 2 are satisfied.
Conditions 3
Area satisfying
conditions 2
ON delay
set time
Area satisfying
conditions 1
Reverse action
Reverse action
Reverse action
Reverse action
Reverse action
Reverse action
Reverse action
Reverse action
ON
HYS
Main setting (0 or more)
Conditions 3
ON delay
PV to be used as reference
Area satisfying
conditions 2
set time
Area satisfying
Main setting (0 or more)
conditions 1
ON
(0 or more)
Time
Time
Time
HYS
Main setting

Related parts for rsa6351p