epm3064a Altera Corporation, epm3064a Datasheet - Page 22

no-image

epm3064a

Manufacturer Part Number
epm3064a
Description
Programmable Logic Device Family
Manufacturer
Altera Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
epm3064a-10TC100
Manufacturer:
ALTERA
0
Part Number:
epm3064a-TC100-10N
Quantity:
200
Part Number:
epm3064a-TC44-10N
Manufacturer:
ALTERA
0
Part Number:
epm3064a-TI44-10N
Manufacturer:
ALTERA
0
Part Number:
epm3064aLC
Manufacturer:
ALTERA
0
Part Number:
epm3064aLC-10
Manufacturer:
ALTERA
0
Part Number:
epm3064aLC44-10
Manufacturer:
ALTREA
Quantity:
3 000
Part Number:
epm3064aLC44-10
Manufacturer:
ALTREA
Quantity:
3 000
Part Number:
epm3064aLC44-10
Manufacturer:
ALTERA
Quantity:
42
Part Number:
epm3064aLC44-10
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
epm3064aLC44-10N
Manufacturer:
ALTERA
Quantity:
1 200
Part Number:
epm3064aLC44-10N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
epm3064aLC44-10NSBCC77
Manufacturer:
ALTERA
Quantity:
15
MAX 3000A Programmable Logic Device Family Data Sheet
Operating
Conditions
22
Symbol
V
V
I
T
T
T
OUT
Table 12. MAX 3000A Device Absolute Maximum Ratings
STG
A
J
CC
I
Supply voltage
DC input voltage
DC output current, per pin
Storage temperature
Ambient temperature
Junction temperature
Parameter
Figure 8. MAX 3000A AC Test Conditions
Tables 12
recommended operating conditions, DC operating conditions, and
capacitance for MAX 3000A devices.
Power supply transients can affect AC
measurements. Simultaneous transitions
of multiple outputs should be avoided for
accurate measurement. Threshold tests
must not be performed under AC
conditions. Large–amplitude, fast–
ground–current transients normally occur
as the device outputs discharge the load
capacitances. When these transients flow
through the parasitic inductance between
the device ground pin and the test system
ground, significant reductions in
observable noise immunity can result.
Numbers in brackets are for 2.5–V
outputs. Numbers without brackets are for
3.3–V devices or outputs.
through
With respect to ground
No bias
Under bias
PQFP and TQFP packages, under bias
15
provide information on absolute maximum ratings,
Conditions
(2)
Note (1)
Device
Output
Device input
rise and fall
times < 2 ns
[521 Ω]
[481 Ω]
703 Ω
620 Ω
Min
–0.5
–2.0
–25
–65
–65
Altera Corporation
Max
5.75
150
135
135
4.6
25
C1 (includes jig
capacitance)
VCC
To Test
System
Unit
mA
° C
° C
° C
V
V