sx1511iultrt Semtech Corporation, sx1511iultrt Datasheet - Page 35

no-image

sx1511iultrt

Manufacturer Part Number
sx1511iultrt
Description
World
Manufacturer
Semtech Corporation
Datasheet
0xXX
0xXX
0x21
0x22
0x23
0x24
0x25
0x26
0x27
0x28
ADVANCED COMMUNICATIONS & SENSING
Rev 1 – 24
RegLEDDriverEnableA
RegDebounceConfig
RegDebounceEnableB
RegDebounceEnableA
RegKeyConfig1
RegKeyConfig2
RegKeyData1
RegKeyData2
RegTOnX
RegIOnX
th
Feb. 2010
0xFF
0xFF
0xFF
0x00
0x00
0x00
0x00
0x00
0x00
0x00
7:0
7:3
2:0
7:0
7:0
6:4
2:0
7:6
5:3
2:0
7:0
7:0
7:5
4:0
7:0
7
3
Enables LED Driver for each [output-configured] IO
0 : LED Driver is disabled
1 : LED Driver is enabled
Unused
Debounce time (Cf. §4.6.1)
000: 0.5ms x 2MHz/fOSC
001: 1ms x 2MHz/fOSC
010: 2ms x 2MHz/fOSC
011: 4ms x 2MHz/fOSC
100: 8ms x 2MHz/fOSC
101: 16ms x 2MHz/fOSC
110: 32ms x 2MHz/fOSC
111: 64ms x 2MHz/fOSC
Enables debouncing for each [input-configured] IO
0 : Debouncing is disabled
1 : Debouncing is enabled
Enables debouncing for each [input-configured] IO
0 : Debouncing is disabled
1 : Debouncing is enabled
Reserved
Auto Sleep time (no key press within this time will set keypad engine to sleep)
000 : OFF
001 : 128ms x 2MHz/fOSC
010 : 256ms x 2MHz/fOSC
011 : 512ms x 2MHz/fOSC
100 : 1sec x 2MHz/fOSC
101 : 2sec x 2MHz/fOSC
110 : 4sec x 2MHz/fOSC
111 : 8sec x 2MHz/fOSC
Unused
Scan time per row (must be set above debounce time).
000 : 1ms x 2MHz/fOSC
001 : 2ms x 2MHz/fOSC
010 : 4ms x 2MHz/fOSC
011 : 8ms x 2MHz/fOSC
100 : 16ms x 2MHz/fOSC
101 : 32ms x 2MHz/fOSC
110 : 64ms x 2MHz/fOSC
111 : 128ms x 2MHz/fOSC
Unused
Number of rows (outputs) + key scan enable
000 : Key scan OFF
001 : 2 rows – IO[0:1]
010 : 3 rows – IO[0:2]
011 : 4 rows – IO[0:3]
100 : 5 rows – IO[0:4]
101 : 6 rows – IO[0:5]
110 : 7 rows – IO[0:6]
111 : 8 rows – IO[0:7]
Number of columns (inputs)
000 : 1 column – IO[8]
001 : 2 columns – IO[8:9]
010 : 3 columns – IO[8:10]
011 : 4 columns – IO[8:11]
100 : 5 columns – IO[8:12]
101 : 6 columns – IO[8:13]
110 : 7 columns – IO[8:14]
111 : 8 columns – IO[8:15]
Column which generated NINT (active low)
Ex: RegKeyData1=11011111 => IO13 has generated NINT
The register is automatically cleared when RegKeyData2 is read.
Row which generated NINT (active low)
Ex: RegKeyData2=11111110 => IO0 has generated NINT
When the register is read both RegKeyData1 & RegKeyData2 are automatically cleared
together with NINT and key scan continues.
Unused
ON Time of IO[X]:
0 : Infinite (Static mode, TOn directly controlled by RegData, Cf §4.9.2)
1 - 15 : TOnX = 64 * RegTOnX * (255/ClkX)
16 - 31 : TOnX = 512 * RegTOnX * (255/ClkX)
ON Intensity of IO[X]
- Linear mode : IOnX = RegIOnX
- Logarithmic mode (fading capable IOs only) : IOnX = f(RegIOnX) , Cf §4.9.5
35
World’s Lowest Voltage Level Shifting GPIO
with LED Driver and Keypad Engine
SX1510/SX1511/SX1512
www.semtech.com