at49bv6416c ATMEL Corporation, at49bv6416c Datasheet - Page 14

no-image

at49bv6416c

Manufacturer Part Number
at49bv6416c
Description
64-megabit 4m X 16 Page Mode 2.7-volt Flash Memory
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at49bv6416c-70CI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49bv6416c-70CI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49bv6416c-70CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49bv6416c-70TI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49bv6416cT-70CI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49bv6416cT-70CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49bv6416cT-70CU-J
Manufacturer:
ATMEL
Quantity:
575
Part Number:
at49bv6416cT-70TI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
3.30
3.28
14
Protection Register Programming
Flowchart
Full Status Check Flowchart
AT49BV6416C(T)
Register Data
Read Status
Successful
SR3, SR4
SR1, SR4
SR1, SR4
Program
Address & Data
Read Status
PR Address
(If Desired)
0
0
Full Status
Complete
0
Write C0,
Write PR
Program
Register
Check
SR7 =
Start
=
=
=
1
1, 1
0, 1
1, 1
0
(Program Setup)
(Confirm Data)
Register Locked;
Program Aborted
V
Program Error
P P
Range Error
3.29
3.31
Operation
Program Protection Register operation addresses must be
within the protection register address space. Addresses
outside this space will return an error.
Repeat for subsequent programming operations.
Full status register check can be done after each program, or
after a sequence of program operations.
Write FF after the last operation to return to the Read mode.
SR3 must be cleared before the Write State Machine allows
further program attempts.
Only the Clear Status Register command clears SR1, SR3,
SR4.
If an error is detected, clear the status register before
attempting a program retry or other error recovery.
Operation
Write
Write
Read
Bus
Bus
Idle
Idle
Idle
Idle
Protection Register Programming
Procedure
Full Status Check Procedure
Command
Command
Protection
PR Setup
Program
Program
None
None
None
None
None
Comments
Data = C0
Addr = First Location to Program
Data = Data to Program
Addr = Location to Program
Status register data: Toggle CE
or
OE to update status register data
Check SR7
1 = WSMS Ready
0 = WSMS Busy
Comments
Check SR1, SR3, SR4:
0,1,1 = V
Check SR1, SR3, SR4:
0,0,1 = Programming Error
Check SR1, SR3, SR4:
1, 0,1 = Sector locked; operation
aborted
PP
Range Error
3465D–FLASH–04/06