s-24c08ci-t8t1u3 Seiko Instruments Inc., s-24c08ci-t8t1u3 Datasheet - Page 11

no-image

s-24c08ci-t8t1u3

Manufacturer Part Number
s-24c08ci-t8t1u3
Description
2-wire Serial Eeprom S-24c08c 8k-bit
Manufacturer
Seiko Instruments Inc.
Datasheet
Rev.2.0
SCL
Operation
SDA
1. Start Condition
2. Stop Condition
Start is identified by a high to low transition of the SDA line while the SCL line is stable at high.
Every operation begins from a start condition.
Stop is identified by a low to high transition of the SDA line while the SCL line is stable at high.
When a device receives a stop condition during a read sequence, the read operation is interrupted, and the device
enters standby mode.
When a device receives a stop condition during a write sequence, the reception of the write data is halted, and the S-
24C08C initiates a write cycle.
_00_H
Start Condition
t
SU.STA
t
HD.STA
Figure 11 Start / Stop Conditions
Seiko Instruments Inc.
2-WIRE CMOS SERIAL E
t
Stop Condition
SU.STO
S-24C08C
2
PROM
11

Related parts for s-24c08ci-t8t1u3